beautypg.com

Delmhorst Instrument Navigator User Manual

Page 16

background image

Copyright

2007, Delmhorst Instrument Co.

Page 16 of 28

3.

The default status of the alarm is “OFF.” Press the SELECT key to turn it on.

4. After the alarm is turned on, use the

п р keys to scroll up or down to a higher or lower

alarm value.

5. After you have selected the alarm value, use the

òkey to highlight DONE. Press SELECT

to get back to the SET ALARM sub menu.

From here, you may continue to set the alarm value for other materials as described above,
or you may scroll to DONE to get back to the MAIN menu.

Default alarm settings in PIN mode are as follows for different materials:

All wood materials:

12%

Sheetrock:

1.0%

Plaster:

68 (on the 0-100 relative scale)

Concrete:

68 (on the 0-100 relative scale)

Note: Default alarm setting for SCAN mode is 300.



TO TAKE A PIN READING:

1.

From the Enhanced Main Menu, use the

с т keys to highlight #2, PIN MODE. If you

are already in the ENHANCED SCAN screen, use the

с т keys to highlight GOTO

PIN.

2. Press the SELECT key to get into the ENHANCED READ screen. The current location

will stay the same while toggling between scan and pin modes.

This screen contains the following information: Job # and ID, current location (LOC),
material, the number of records for the current room (REC), and memory used (MEM).

3. Insert the pins into the material, press the SELECT key and the meter will start taking

measurements. Press SELECT again to store the measurement. The meter will display
HOLD. Once you have stored a reading, the meter will automatically increment to the
next available location. Remove the pins from the material, press SELECT, and move to
the next defined location as indicated on the display.