Avigilon Control Center System Integration Guide with Gallagher Command Centre
15
Troubleshooting
If the following troubleshooting solutions do not resolve your issue, contact Avigilon Technical
Support –
Avigilon Gallagher Integration Fails
After you install the integration, you are able to add the Avigilon server and cameras but all the
devices are displayed as offline in the Gallagher software. When you open the Avigilon Control
Center Client software, the server and cameras are online and functioning.
The issue may occur if there is a port conflict between Gallagher Command Centre and the
Gallagher Controller API (FTCAPI). To resolve the issue, complete the following steps:
1. Make sure the FTCAPI is installed on the Gallagher Command Centre Server.
2. Set the Gallagher Controller IP port. Refer to the “API Location” topic in the Gallagher
Controller API Developers Guide.
3. Verify that FTCAPI is installed correctly by running the FTCAPI test harness. It should
start with no errors.
When you launch the Gallagher Command Centre software again, the Avigilon server and
cameras should be listed as online.
Avigilon Camera Will Not Display Video
You are unable to watch live video from an Avigilon camera and a
symbol is displayed over the
camera in the Gallagher software. When you try to display live video from the same camera in the
Avigilon Control Center software, it displays correctly.
This issue occurs if the integration was unable to connect with the camera. Confirm the following
then test the connection again:
•
The camera is connected to the Avigilon Server it was assigned to in the
Gallagher Camera Setup procedure.
•
The camera’s logical ID matches the Identification assigned to the camera during
the Gallagher Camera Setup procedure.
•
The FTCAPI was installed properly.
•
The installation and configuration procedures were completed in full.