4.5-B GASDRY PEAK DESICCANT
The general purpose tablet is reccommended for installations where
inlet gas temperature is 80
o
F or lower. Depending on the pressure and
temperature, GasDry Peak can provide a residual moisture content
below 5 lbs/MMSCF.
Chart 3 shows the level of dryness that GasDry Peak provides at
different conditions.
Chart 4 shows an approximate consumption rate for GasDry Peak
at several conditions. Use the charts for guidelines to calculate the
approximate consumption rate of the desiccant.
CHART 3
MOISTURE CONTENT OF GAS (LBS. H2O/MMSCF)
AFTER DEHYDRATOR WITH GASDRY PEAK
CHART 2
GASDRY PRIME CONSUMPTION RATE
(LBS./MMSCF)
INLET
TEMP
100
o
F
95
o
F
90
o
F
85
o
F
80
o
F
75
o
F
70
o
F
65
o
F
60
o
F
55
o
F
50
o
F
100
PSIG
40.9
35.1
30.2
25.8
22.0
18.6
15.7
13.3
11.2
9.4
7.8
INLET
TEMP
80
o
F
75
o
F
70
o
F
65
o
F
60
o
F
55
o
F
50
o
F
45
o
F
500
PSIG
18.6
15.9
13.5
11.5
9.7
8.2
6.9
5.8
100
PSIG
72.5
61.5
51.9
43.9
37.0
30.9
25.8
21.5
400
PSIG
22.3
19.0
16.1
13.7
11.6
9.7
8.2
6.8
200
PSIG
40.2
34.2
28.9
24.5
20.7
17.3
14.5
12.0
600
PSIG
16.1
13.7
11.7
10.0
8.4
7.1
6.0
5.0
300
PSIG
28.4
24.2
20.5
17.4
14.7
12.3
10.3
8.6
720
PSIG
14.0
11.9
10.2
8.7
7.4
6.2
5.2
4.4
CHART 4
GASDRY PEAK CONSUMPTION RATE (LBS./MMSCF)
INLET
TEMP
80
o
F
75
o
F
70
o
F
65
o
F
60
o
F
55
o
F
50
o
F
45
o
F
500
PSIG
17.2
14.6
12.5
10.6
9.0
7.6
6.4
5.3
100
PSIG
66.9
56.7
47.9
40.5
34.1
28.5
23.8
19.8
400
PSIG
20.6
17.6
14.9
12.6
10.7
9.0
7.6
6.3
200
PSIG
37.1
31.5
26.7
22.6
19.1
15.9
13.3
11.1
600
PSIG
14.9
12.7
10.8
9.2
7.8
6.6
5.5
4.6
300
PSIG
26.3
22.3
18.9
16.0
13.6
11.4
9.5
7.9
720
PSIG
12.9
11.0
9.4
8.0
6.8
5.8
4.8
4.1
4.5-B GASDRY MAX DESICCANT
Where extremely dry gas is required or where operating pressure is
low, GasDry Max tablets provide a lower residual moisture content.
Chart 5 shows the level of dryness that GasDry Max will provide at
different conditions.
Chart 6 shows an approximate consumption rate for GasDry Peak
at several conditions. Use the charts for guidelines to calculate the
approximate consumption rate of the desiccant.
CHART 5
MOISTURE CONTENT OF GAS (LBS.H2O/MMSCF)
AFTER DEHYDRATOR WITH GASDRY MAX
INLET
TEMP
100
o
F
95
o
F
90
o
F
85
o
F
80
o
F
75
o
F
70
o
F
65
o
F
60
o
F
55
o
F
50
o
F
45
o
F
40
o
F
500
PSIG
13.4
11.5
10.0
8.5
7.3
6.3
5.3
4.5
3.8
3.2
2.7
2.3
1.9
100
PSIG
53.1
45.6
39.2
33.5
28.6
24.2
20.5
17.3
14.6
12.2
10.2
8.5
7.0
400
PSIG
16.1
13.9
12.0
10.3
8.8
7.5
6.4
5.4
4.6
3.8
3.2
2.7
2.2
200
PSIG
29.3
25.2
21.7
18.5
15.8
13.5
11.4
9.6
8.1
6.8
5.7
4.7
3.9
600
PSIG
11.5
10.0
8.6
7.4
6.3
5.4
4.6
3.9
3.3
2.8
2.4
2.0
1.7
300
PSIG
20.6
17.8
15.3
13.1
11.2
9.5
8.1
6.9
5.8
4.8
4.1
3.4
2.8
720
PSIG
10.0
8.6
7.5
6.4
5.5
4.7
4.0
3.4
2.9
2.5
2.1
1.7
1.5
CHART 6
GASDRY MAX CONSUMPTION RATE (LBS./MMSCF)
INLET
TEMP
100
o
F
95
o
F
90
o
F
85
o
F
80
o
F
75
o
F
70
o
F
65
o
F
60
o
F
55
o
F
50
o
F
45
o
F
40
o
F
500
PSIG
29.8
25.8
22.2
19.1
16.4
13.9
11.9
10.1
8.6
7.2
6.1
5.1
4.2
100
PSIG
118.5
101.8
87.5
74.7
63.7
54.0
45.6
38.6
32.5
27.1
22.7
18.9
15.6
400
PSIG
36.0
31.0
26.8
22.9
19.6
16.7
14.2
12.0
10.2
8.6
7.2
6.0
5.0
200
PSIG
65.4
56.2
48.4
41.4
35.3
30.0
25.4
21.5
18.2
15.2
12.7
10.6
8.8
600
PSIG
25.7
22.2
19.2
16.5
14.2
12.1
10.3
8.8
7.4
6.3
5.3
4.4
3.7
300
PSIG
46.0
39.6
34.1
29.2
25.0
21.3
18.0
15.3
12.9
10.8
9.1
7.6
6.3
720
PSIG
22.2
19.2
16.6
14.3
12.3
10.5
9.0
7.6
6.5
5.5
4.6
3.9
3.2
NOTE
MMSCF is 1,000,000 STANDARD CUBIC FEET
200
PSIG
22.5
19.4
16.7
14.3
12.2
10.4
8.8
7.4
6.3
5.2
4.4
300
PSIG
15.9
13.7
11.8
10.1
8.6
7.3
6.2
5.3
4.5
3.7
3.1
400
PSIG
12.4
10.7
9.2
7.9
6.8
5.8
4.9
4.2
3.5
3.0
2.5
500
PSIG
10.3
8.9
7.7
6.6
5.6
4.8
4.1
3.5
3.0
2.5
2.1
600
PSIG
8.9
7.7
6.6
5.7
4.9
4.2
3.6
3.0
2.6
2.2
1.8
720
PSIG
7.7
6.6
5.7
4.9
4.2
3.6
3.1
2.6
2.2
1.9
1.6