beautypg.com

5 desiccant consumption, 4 bed level guide – Van Air Systems PLD 8-7.2 / 36-7.2 User Manual

Page 6

background image

PAGE 6

FIGURE 4-A BED LEVEL DETAIL

The level of the desiccant bed should be maintained as close to
the MAXIMUM level as possible. The bed level should not be
allowed to fall below the MINIMUM level. Dehydrator performance
will be effected. Reference Figure 4-A for levels and quantities.

With the fi ll port cover removed, use a measuring stick to deter-
mine the distance from the top of the fi ll opening to the top of the
desiccant bed. Reference Figure 4-A. Add desiccant as required
to bring desiccant bed to maximum level.

CAUTION

Never fi ll the vessel above the MAXIMUM LEVEL.
Filling the vessel above the MAXIMUM level may
effect the performance of the dehydrator.

The desiccant bed level should be checked regularly. Section
4.5 DESICCANT CONSUMPTION will help you estimate the
amount of desiccant that the dehydrator should use, based on

operating conditions.

4.5 DESICCANT CONSUMPTION

Consumption rate based on average conditions. Actual condi-
tions can vary.

4.4 BED LEVEL GUIDE

MODEL

PLD 8-7.2

PLD 12-7.2

PLD 16-7.2

PLD 20-7.2

PLD 24-7.2

PLD 30-7.2

PLD 36-7.2

C

Dim. To

MIN LEVEL

31-1/16"

30-3/8"

31-1/4"

30-1/4"

31-1/2"

33-1/16"

34-7/8"

MODEL

PLD 8-7.2

PLD 12-7.2

PLD 16-7.2

PLD 20-7.2

PLD 24-7.2

PLD 30-7.2

PLD 36-7.2

PRE-BED

CERAMIC

BEAD

16 LBS

35 LBS

55 LBS

89 LBS

126 LBS

199 LBS

318 LBS

DRYING

GASDRY

PEAK

48 LBS

148 LBS

236 LBS

379 LBS

537 LBS

853 LBS

1361 LBS

DRYING

GASDRY

MAX

52 LBS

161 LBS

258 LBS

413 LBS

586 LBS

930 LBS

1484 LBS

B

Dim. To

Pre-Bed

46-1/16"

51-3/8"

52-1/4"

51-1/4"

52-1/2"

54-1/16"

55-7/8"

DRYER DIMENSIONS-

INCHES

D

Dim. To

MAX LEVEL

16-1/16"

10-3/8"

10-1/4"

9-1/4"

10-1/2"

12-1/16"

13-7/8"

A

Dim. To

Grid

52-1/16"

57-3/8"

58-1/4"

57-1/4"

58-1/2"

60-1/16"

61-7/8"

4.5-A GASDRY PRIME DESICCANT

This general purpose tablet is recommended for installations
where inlet gas temperature is 100

o

F or lower. Depending on the

pressure and temperature, GasDry Prime can provide a residual
moisture content below 9 lbs/mmscf.

Chart 1 shows the level of dryness that GasDry Prime will provide
at different conditions.

Chart 2 shows an approximate consumption rate for GasDry Prime
at several conditions. Use the charts for guidelines to calculate the
approximate consumption rate of the desiccant.

CHART 1

MOISTURE CONTENT OF GAS (LBS. H2O/MMSCF)
AFTER DEHYDRATOR WITH GASDRY PRIME

INLET
TEMP

100

o

F

95

o

F

90

o

F

85

o

F

80

o

F

75

o

F

70

o

F

65

o

F

60

o

F

55

o

F

50

o

F

200

PSIG

124.0

106.6

91.7

78.4

67.0

56.9

48.2

40.8

34.4

28.8

24.1

100

PSIG

224.7

193.1

165.9

141.6

120.8

102.5

86.6

73.2

61.7

51.4

43.0

400

PSIG

68.3

58.9

50.8

43.5

37.2

31.7

26.9

22.8

19.4

16.2

13.6

500

PSIG

56.6

48.8

42.2

36.1

31.0

26.5

22.5

19.1

16.2

13.6

11.5

600

PSIG

48.8

42.1

36.4

31.2

26.8

22.9

19.5

16.6

14.1

11.9

10.0

300

PSIG

87.2

75.1

64.7

55.4

47.4

40.3

34.2

29.0

24.5

20.5

17.2

720

PSIG

42.2

36.5

31.6

27.1

23.3

19.9

17.0

14.5

12.3

10.4

8.7

NOTE

MMSCF is 1,000,000 STANDARD CUBIC FEET

DRYING

GASDRY

PRIME

63 LBS

193 LBS

309 LBS

496 LBS

704 LBS

1116 LBS

1781 LBS