beautypg.com

Van Air Systems SG-23 Cartridge User Manual

Disposable cartridge sg-23, Installation instructions

background image

August 2008

432-00160-B

WHEN TO REPLACE CARTRIDGE:

Crystals in cartridge as seen through sight window of

housing will change from blue to pink when silica gel in cartridge
is saturated with moisture. Install fresh cartridge when crystals
turn to pink.

BOSS (INSTALL CARTRIDGE
HERE)

O-RING
GROOVE

VIEW FROM BOTTOM OF DRYER HEAD

DRYER WITH CARTRIDGE

CLAMP

1/4" BALL VALVE

BOWL

BEFORE INSTALLING NEW CARTRIDGE, READ THE
FOLLOWING INSTRUCTIONS CAREFULLY.

DO NOT REMOVE BOWL FROM DRYER HEAD UNTIL
VESSEL IS COMPLETELY DEPRESSURIZED.

REPLACING OLD CARTRIDGE:

Close inlet and outlet shutoff valves (and open bypass if
provided); or lock out all compressed air supply to dryer
housing.
Slowly open ball valve on bottom of housing and allow unit to
depressurize completely.

Grasp bottom portion of housing (Bowl) with one hand and
turn clamp knob with the other to loosen. Slide clamp down
and off vessel.
Remove used cartridge from head and discard the cartridge.
Remove new cartridge from packaging.
Push new cartridge onto boss of dryer head.
Reinstall bowl and clamp. Make sure that the bowl is tight
against the head and the o-ring is correctly seated in the
groove.
Close the ball valve and slowly pressurize the vessel. If any
leaks occur, depressurize vessel completely and correct the
problem before repressurizing.

1.

2.

3.

4.
5.
6.
7.

8.

WARNING

WARNING

INSTALLATION INSTRUCTIONS

DISPOSABLE CARTRIDGE SG-23

FOR IN-LINE DESICCANT DRYER MODEL ID15/SW

AND MINI DRYER MODEL MD4/SW

VAN AIR PART NUMBER: 26-0888

SIGHT
WINDOW

OUTLET
1/2" NPT

INLET
1/2" NPT

A

B

SG-23 SILICA GEL

CARTRIDGE

HEAD

2950 Mechanic Street

Lake City, PA 16423-2095

Phone: 814-774-2631

Fax: 814-774-3482

www.vanairsystems.com