2 troubleshooting sct® equipped implements – Seed Hawk TOOLBAR 2013 45 & XL SERIES User Manual
Page 57
![background image](/manuals/364505/57/background.png)
SEED HAWK® TOOLBAR OPERATOR’S MANUAL
57
8.2 TROUBLESHOOTING SCT® EQUIPPED IMPLEMENTS
SYMPTOM
POSSIBLE CAUSE
SOLUTION
Gates will not
open/close
No hydraulic pressure to
meter block
Engage hydraulic circuit (wing down)
Check SCT node
Check lights on front of node
Meter block PRV (pressure
relief valve) set to low
Increase PRV pressure until gates cycle (do not exceed 500 psi)
No power at coils
Turn master switch on
Check fuses
Check connections at coil and SCT node
Openers will not
lift
No hydraulic pressure to
meter block
Engage hydraulic circuit (Opener)
BFJ (pressure relief block)
set to low
Increase pressure (factory set to 1800 psi)
No power at coils
Turn master switch on
Check fuses
Check connections
Wing down
switch will not
work
No hydraulic pressure
Engage hydraulic circuit (wing down)
Master switch on
Turn master switch off (unfold only)
Random opener
sections lifting
Improper look aheads
Ensure that the look ahead number is not a negative number.
Agressiveness set to high
Turn aggressiveness off
Improper drill setup
Check drill setup
Meter roller
wont turn
No hydraulic pressure
Engage hydraulic circuit (wing down)
Product control switch is
off
Turn product control switch to auto
Roller is jammed
Remove roller from meter body and remove obstruction from
meter.
Check air cart node
Check lights on front of node
Check meter settings
Make sure that the meter cal and cal wieght is entered
correctly
No fan speed
Fan sensor out of
alignment
Check and re‐align sensor if necessary.
Fan cal is incorrect
Set fan cal to 2
No hydraulic pressure
Diverter block is set to the
auger/conveyor position
Set diverter to the fan position
No tractor
speed
Speed settings set
incorrectly
Outer opener
sections engage
when turning
No field boundry recorded
Create a field boundry
Agressiveness is on
Turn aggressiveness off
Improper look aheads
Adjust look ahead time
Meter gate
alarms going off
Proximity sensors on gates
misaligned
Align proximity sensors
Gates not functioning
See “gates will not open/close”
Proximity sensor damaged
Replace proximity sensor