beautypg.com

0 specifications, 1 hardware torque, 1 sae – Seed Hawk TOOLBAR 2013 45 & XL SERIES User Manual

Page 19: 2 metric, 3 flare‐type tube fittings, Seed hawk® toolbar operator’s manual 19

background image

SEED HAWK® TOOLBAR OPERATOR’S MANUAL 

 19 




3.0 SPECIFICATIONS 

3.1 HARDWARE TORQUE 

 

NOTE:  DO  NOT  use  the  values  in  the  Bolt  Torque  Charts  if  a  different  torque  value  or 
tightening procedure is given for a specific application. 

3.1.1  SAE 

Bolt Diameter 

Bolt Torque

 

inches 

SAE 5

N∙m (lb‐ft) 

SAE 8 

N∙m (lb‐ft) 

1/4 

11 (8)

16 (12) 

5/16 

23 (17)

33 (24) 

3/8 

41 (30)

61 (45) 

7/16 

68 (50)

95 (70) 

1/2 

110 (80)

155 (115) 

9/16 

149 (110)

210 (155) 

5/8 

203 (150)

285 (210) 

3/4 

366 (270)

508 (375) 

7/8 

536 (395)

827 (610) 

800 (590)

1234 (910) 

 

3.1.2  METRIC 

Bolt Diameter 

Bolt Torque 

 

mm 

8.8 

N∙m (lb‐ft) 

10.9 

N∙m (lb‐ft) 

M3 

0.5 (0.4) 

1.8 (1.3) 

M4 

3 (2.2) 

4.5 (3.3) 

M5 

6 (4) 

9 (7) 

M6 

10 (7) 

15 (11) 

M8 

25 (18) 

35 (26) 

M10 

50 (37) 

70 (52) 

M12 

90 (66) 

125 (92) 

M14 

140 (103) 

200 (148) 

M16 

225 (166) 

310 (229) 

M20 

435 (324) 

610 (450) 

M24 

750 (555) 

1050 (774) 

M30 

1495 (1103) 

2100 (1550) 

M36 

2600 (1917)

3675 (2710) 

 

3.1.3  FLARE‐TYPE TUBE FITTINGS 

Tube Size 

OD 

 

in 

Nut Size 

across flats 

 

in 

Torque

 
 

N∙m (lb‐ft) 

Recommended # Turns (after finger tightening) 

turns (flats) 

3/16 

7/16 

8 (6)

1/6 (1) 

1/4 

9/16 

12 (9)

1/6 (1) 

5/16 

5/8 

16 (12)

1/6 (1) 

3/8 

11/16 

24 (18)

1/6(1) 

1/2 

7/8 

46 (34)

1/6 (1) 

5/8 

62 (46)

1/6 (1) 

3/4 

1‐1/4 

102 (75)

1/8 (0.75) 

7/8 

1‐3/8 

122 (90)

1/8 (0.75)