6 winging down 7‐plex toolbars, 7 opener shank operation – toolbar only – Seed Hawk TOOLBAR 2013 45 & XL SERIES User Manual
Page 31
SEED HAWK® TOOLBAR OPERATOR’S MANUAL
31
4.6 WINGING DOWN 7‐PLEX TOOLBARS
NOTE: Please ensure your case drain YELLOW banded hose(s) are connected to the tractor
circuit which is plumbed directly to the reservoir first. If the control box has a 7‐ plex wing
down button please use the following 2 steps to lower the wings safely. Ensure control box is
powered up with 12v. Ensure the case drain(s) gauge on hydraulic block never exceeds 100
PSI, excessive amounts of pressure will damage the gauge.
1. Engage the lever in the tractor cab that the GREEN banded hoses are hooked to (which
lowers your main wings), press and hold the “WING DOWN” switch until all wings are on the
ground. Also used for 50’ & 60’ 45 series toolbars. REFER TO SECTION 4.5, pertaining to the
control system being used.
2. Release switch and leave the lever (that your GREEN banded hoses are hooked to) in
working position “NOT FLOAT”.
4.7 OPENER SHANK OPERATION – TOOLBAR ONLY
1. Ensure that there is power going to the Seed Hawk switch control box. Ensure that balls
values on the back of opener hydraulic manifold are open.
2. Engage the tractor hydraulics lever that the RED band hose (opener circuit) are connected
to.
3. Lock the tractor hydraulics lever that the GREEN banded hoses (wing circuit) are connected
to. The full tractor pressure is shown on the top right (4000 PSI gauge) of the hydraulic
manifold block.
4. Moving in a forward direction, turn on the “PWM DOWN PRESSURE” switch, then turn on
the “SHANK /LIQUID PUMP” switch on. This will engage the opener shanks. REFER TO
SECTION 4.5, pertaining to the control system being used.
FULL TRACTOR