beautypg.com

8 opener shank operation – loup iii – Seed Hawk TOOLBAR 2013 45 & XL SERIES User Manual

Page 32

background image

SEED HAWK® TOOLBAR OPERATOR’S MANUAL 

 32 




NOTE:  In  order  to  get  the  proper  packing  and  penetrating  forces  per  field,  we  recommend 
lowering  the  opener  shank  pressure  from  the  tractor  at  the  beginning  of  each  field.    Every 
new  Seed  Hawk  toolbar  manufactured  leaves  with  the  opener  shank  pressure  set  at 
approximately 1000 PSI.  
 
5.    Turing  the  min‐max  “DOWN  PRESSURE”  dial  allows  the  user  to  increase  or  decrease  the 
desired packing pressure to achieve proper packing and penetration forces to seed. REFER TO 
SECTION 4.5, pertaining to the control system being used.   
 
NOTE: The chain between the seed and fertilizer knife will be tight when applying the proper 
amount  of  pressure  to  the  opener  shank.    Once  the  knives  get  tight,  notice  the  shank 
pressure gauge and its reading.  In good seeding conditions, add an additional 200 PSI to the 
system.  When seeding small seeds such as CANOLA in wet conditions, adding an additional 
200 PSI is not recommended.  This would cause over compaction.  Max packing pressure is 
1500 PSI.  

6.    Turn  off  the  “SHANK  /LIQUID  PUMP”  switch  to  disengage  the  opener  shanks.    Refer  to 
picture above.  REFER TO SECTION 4.5, pertaining to the control system being used.   
 
NOTE:  ALWAYS  ENSURE  THAT  THE  OPENER  SHANK  IS  MAINTAINING  SEED  AND  FERTILIZER 
SEPERATION.  SEED HAWK INC. RECOMMENDS CHECKING THE ACTUAL SEED AND FERTILIZER 
SEPERATON  IN  EACH  FIELD.    SOILS  VARY,  MOISTURE  CONDITIONS  VARY.    OVER  TIME  THE 
OPENER BOLTS IF NOT TIGHTENED ON A YEARLY BASIS WILL FUNCTION DIFFERENTLY FROM 
THE NEW MACHINE, SEED AND FERTILIZER SEPERATION MAY CHANGE. 
 

4.8 OPENER SHANK OPERATION – LOUP III 

 
1. Ensure that there is power going to the Seed Hawk LOUP III monitor. 
 
2.  Engage the tractor hydraulics lever that the RED band hose (opener circuit) are connected 
to. 
 
3.  Lock the tractor hydraulics lever that the GREEN banded hoses (wing circuit) are connected 
to.    The  full  tractor  pressure  is  shown  on  the  top  right  (4000  PSI  gauge)  of  the  hydraulic 
manifold block.   

 
 
 
 
 
 
 

FULL TRACTOR 

PRESSURE