Label markings – LumaSense Technologies M8100SM-EXP User Manual
Page 57

E
2
T QUASAR Flare Monitors Operation Manual
Appendix B: Area Classification/Protection
Concepts 57
Appendix B: Area Classification/Protection
Concepts
Label Markings
European Markings and Classification for the M8100-EXP
CENELEC : European Committee Norms for Standardization ELECtrical Equipment
CE Declaration and Notified Body Markings:
CSA Markings and Classification for the QUASAR M8100-EXP.
European Community Explosion protection standard and environment:
Ex d "Flameproof Enclosure" Protection Type, CENELEC standard: EN 50018, 2002; by method of
containing the explosion, prevents flame propagation in the event of a failure
IIB: Explosion Proof Gas Grouping based on type testing
Temperature code T4: maximum surface temperature will not exceed 275 °F (135 °C) Pertinent
when considering gas ignition temperatures that may come in contact.
Equipment Group II: Above ground, High level, Single fault protection required
Equipment Category 2: Electrical in Hazardous areas, excluding Mining
Explosive Atmosphere Type G: Gas, vapor or mist.
Area Classification: Zone 1
Equipment Group II and Equipment Category 2
II 2 G, EEx d IIB T4 (X)
0344
II 2 G, EEx d IIB T4
KEMA 03ATEX2379
CE declaration mark, conformance to applicable Equipment Directives
Notified Body Identification number involved in quality of manufacturing
systems
Identification of the Notified Body providing product certification, followed by
the ATEX EC-Type examination certificate number.