LT Security LTD7904 User Manual
Page 36

30
Digital Video Recorder User Manual
Step3: the setup steps of motion trigger are familiar with alarm handling; user can refer to Chapter 4.5.1 Sensor
alarm
handling for more details.
Step4: click Area button to pop-up a window as Fig 4-24:
Fig 4-24 motion-area
Step5: in the Area interface, user can drag slide bar to set the sensitivity value (1-8). The default value is 4. The higher the
value is the higher sensitivity you get. Due to the sensitivity is influenced by color and time (day or night), user can adjust its
value according to the practical conditions; click
icon to set the whole area as detection area; click
icon and then the
set detection area will be cleared; click
icon to test whether the sensitivity value and motion area are suitable accordingly
(please refer to following picture); Click
icon, to save the setting; click
icon, exit current interface.
Note: when user drag mouse to set motion detection area, they have to click
icon to clear all set detection area
firstly, and then make the operation.
Step6: user can also setup all channels with same parameters.
Step7: click “default” button to resort default setting; click “apply” button to save the setting; click “exit” button to exit current
interface.
② Schedule