beautypg.com

Installation – Lincoln Electric IM707 Commander 500 User Manual

Page 9

background image

A-1

INSTALLATION

COMMANDER 500 CUMMINS

A-1

TECHNICAL SPECIFICATIONS - COMMANDER 500 CUMMINS (K1846-1 & -2)

Make/Model

Description

Speed (RPM)

Displacement

Starting

Capacities

System

Cummins

4 cylinder

High Idle 1900

199 cu. in

12VDC battery

Fuel: 25 gal.

B3.3

56 HP(42kw)

Low Idle 1475

(3.3 L)

& Starter

94.6 L

Diesel Engine

@ 1800 RPM

Full Load 1800

Bore x Stroke

Oil: 8.0 Qts.

7.5L

3.74” x 4.53”

(95mm x 115mm)

Coolant: 2.6 Gal.

11.8 L

INPUT - DIESEL ENGINE

RATED OUTPUT - WELDER

HEIGHT

2

WIDTH

DEPTH

WEIGHT

42.0 in.

31.5 in.

63.1 in.

1625 lbs.(737 kg)

( Approx.)

1066.8 mm

800.1 mm

1602.7 mm

OUTPUT - WELDER AND GENERATOR

Duty Cycle

Welding Output

Volts at Rated Amps

100%

500 Amps (DC multi-purpose)

40 Volts

60%

550 Amps (DC multi-purpose)

36 Volts

50%

575 Amps (DC multi-purpose)

35 Volts

Welding Range

Open Circuit Voltage

Auxiliary Power

1

30 - 575 Amps CC/CV

80 Max OCV @1900 RPM

120/240 VAC
12,000 Watts, 60 Hz.

20 - 250 Amps TIG

100% Duty Cycle

PHYSICAL DIMENSIONS

1. Output rating in watts is equivalent to volt-amperes at unity power factor.

Output voltage is within +/- 10% at all loads up to rated capacity. When welding, available auxiliary power will be reduced.

2. Top of Enclosure. Add 5.6” (142.2mm) for exhaust.