Installation – Lincoln Electric IM707 Commander 500 User Manual
Page 9

A-1
INSTALLATION
COMMANDER 500 CUMMINS
A-1
TECHNICAL SPECIFICATIONS - COMMANDER 500 CUMMINS (K1846-1 & -2)
Make/Model
Description
Speed (RPM)
Displacement
Starting
Capacities
System
Cummins
4 cylinder
High Idle 1900
199 cu. in
12VDC battery
Fuel: 25 gal.
B3.3
56 HP(42kw)
Low Idle 1475
(3.3 L)
& Starter
94.6 L
Diesel Engine
@ 1800 RPM
Full Load 1800
Bore x Stroke
Oil: 8.0 Qts.
7.5L
3.74” x 4.53”
(95mm x 115mm)
Coolant: 2.6 Gal.
11.8 L
INPUT - DIESEL ENGINE
RATED OUTPUT - WELDER
HEIGHT
2
WIDTH
DEPTH
WEIGHT
42.0 in.
31.5 in.
63.1 in.
1625 lbs.(737 kg)
( Approx.)
1066.8 mm
800.1 mm
1602.7 mm
OUTPUT - WELDER AND GENERATOR
Duty Cycle
Welding Output
Volts at Rated Amps
100%
500 Amps (DC multi-purpose)
40 Volts
60%
550 Amps (DC multi-purpose)
36 Volts
50%
575 Amps (DC multi-purpose)
35 Volts
Welding Range
Open Circuit Voltage
Auxiliary Power
1
30 - 575 Amps CC/CV
80 Max OCV @1900 RPM
120/240 VAC
12,000 Watts, 60 Hz.
20 - 250 Amps TIG
100% Duty Cycle
PHYSICAL DIMENSIONS
1. Output rating in watts is equivalent to volt-amperes at unity power factor.
Output voltage is within +/- 10% at all loads up to rated capacity. When welding, available auxiliary power will be reduced.
2. Top of Enclosure. Add 5.6” (142.2mm) for exhaust.