beautypg.com

Troubleshooting, Caution – Lincoln Electric IM707 Commander 500 User Manual

Page 34

background image

E-2

TROUBLESHOOTING

E-2

COMMANDER 500 CUMMINS

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local
Lincoln Authorized Field Service Facility
for technical troubleshooting assistance before you proceed.

CAUTION

ENGINE PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

Major Physical or Electrical Damage
is Evident.

Engine will not “crank”.

Engine will “crank” but not start.

Engine shuts down shortly after
starting.

Battery does not stay charged.

1. Battery is low. Charge Battery.

2. Loose battery cable connections.

Inspect, clean and tighten.

1. Out of fuel. Fill fuel tank.

2. Fuel shut off valve is in off

position.

3. High coolant temperature

(Indicator light lit. Check engine
cooling system.

4. Low battery voltage.

1. Low fuel. (Indicator light lit

K1846-2 only) Add fuel.

2. Low output of battery charging

alternator. (Indicator light lit)
Check

cooling blower

belt.

Replace if neccessary.

3. High coolant temperature

(Indicator light lit). Check engine
cooling system.

1. Faulty battery. Replace.

If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.

1. Contact your Local Lincoln Authorized