A-9

INSTALLATION

COMMANDER 500 CUMMINS

A-9

CONNECTION OF AN LN-23P WIRE
FEEDER TO THE COMMANDER 500 CUM-
MINS

• Shut the welder off.

• Connect the LN-23P per instructions on the appro-

priate connection diagram in the DIAGRAMS sec-
tion. (NOTE): When connecting an LN-23P to the
COMMANDER 500 CUMMINS, a K350-1 adapter kit
must be used.

• Set the “WIRE FEEDER VOLTMETER” switch to “-”.

• Set the “SELECTOR” switch to “CV-WIRE” position.

• Set the “WELDING TERMINALS”

switch to

“REMOTELY CONTROLLED”.

• Set the ARC CONTROL to desired crispness. SOFT

for MIG - CRISP for INNERSHIELD.

• Set the “IDLE” switch to the “HIGH” position. If you

are using an LN-23P with the K350-1 adapter kit, the
electrode is not energized until the gun trigger is
closed.

CONNECTION OF AN NA-3 AUTOMATIC
WELDING SYSTEM TO THE COMMANDER
500 CUMMINS

For connection diagrams and instructions for connect-
ing an NA-3 Welding System to the COMMANDER 500
CUMMINS, refer to the NA-3 Welding System instruc-
tion manual. The connection diagram for the LN-8 can
be used for connecting the NA-3.

CONNECTION OF AN LN-742 TO THE
COMMANDER 500 CUMMINS

• Shut the welder off.

• Connect the LN-742 per instructions on the appro-

priate connection diagram in the DIAGRAMS sec-
tion.

• Set the “WIRE FEEDER VOLTMETER” switch to

either “+” or “-” as required by the electrode being
used.

• Set the “SELECTOR” switch to the “CV-WIRE” posi-

tion.

• Adjust the “ARC CONTROL” knob to desired

Crispness.

SOFT for MIG and CRISP for

INNERSHIELD.

• Set the “WELDING TERMINALS” switch to the

“REMOTELY CONTROLLED” position.

• Set the “IDLE” switch to the “AUTO” position. When

not welding, the COMMANDER 500 CUMMINS
engine will be at the low idle speed.