D-3

MAINTENANCE

D-3

COMMANDER 500 CUMMINS

Table D.1 Engine Maintenance Components

ITEM

Air Cleaner Element

Oil Filter

Fan Belt

Fuel Strainer

Fuel Filter /

Water Separator

Battery

Engine Oil Change

MAKE

Donaldson

AC

Fleetguard

Cummins

Fleetguard

Cummins

Cummins

Fleetguard

Cummins

Fleetguard

-––––––

See Manual

PART NUMBER

P181052

A302C

AF437K

C6002112110

LF3855

C0412021748

3826094

FF5079

C6003112120

FS19594

BCI GROUP 34

–––––––––

SERVICE INTERVAL

Replace every 200 hours. (Replace more

often when used in dusty and / or

high ambient temperature conditions).

Replace every 750 hours or 3 months,

whichever is less.

Inspect every 1000 hours or 12 months,

whichever is less.

Inspect and replace monthly, as

required. Replace annualy.

Replace every 500 hours or 6 months,

whichever is less.

Inspect every 500 hours.

Change every 750 hours or 3 months,

whichever is less. Check daily.

CHARGING THE BATTERY

When you charge, jump, replace, or otherwise connect
battery cables to the battery, be sure the polarity is cor-
rect. Improper polarity can damage the charging cir-
cuit. The Commander positive (+) battery terminal has
a red terminal cover.

If you need to charge the battery with an external
charger, disconnect the negative cable first, then the
positive cable before you attach the charger leads.
after the battery is charged, reconnect the positive bat-
tery cable first and the negative cable last. Failure to
do co can result in damage to the internal charger
components.

Follow the instructions of the battery charger manufac-
turer for proper charger settings and charging time.

NAMEPLATES / WARNING DECALS
MAINTENANCE

Whenever routine maintenance is performed on this
machine - or at least yearly - inspect all nameplates
and labels for legibility. Replace those which are no
longer clear. Refer to the parts list for the replacement
item number.

WELDER / GENERATOR
MAINTENANCE

STORAGE

Store the Commander in clean, dry protected areas.

CLEANING

Blow out the generator and controls periodically with
low pressure air. do this at least once a week in partic-
ularly dirty areas.

BRUSH REMOVAL AND REPLACEMENT

It is normal for the brushes and slip rings to wear and
darken slightly. Inspect the brushes when a generator
overhaul is necessary.

Do not attempt to polish slip rings while the engine
is running.

------------------------------------------------------------------------