E-3

TROUBLESHOOTING

E-3

POWER MIG (140, 180 MODELS)

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS
(SYMPTOMS)

No wire feed when gun trigger is
pulled. Fan runs, gas flows and
machine has correct open circuit
voltage (33V) – weld output.

POSSIBLE
CAUSE

1. If the wire drive motor is running

make sure that the correct drive
rolls are installed in the machine.

2. Check for clogged cable liner or

contact tip.

3. Check for proper size cable liner

and contact tip.

RECOMMENDED
COURSE OF ACTION

If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service
Facility.

FEEDING PROBLEMS

PROBLEMS
(SYMPTOMS)

Low or no gas flow when gun
trigger is pulled. Wire feed, weld
output and fan operate normally.

POSSIBLE
CAUSE

1. Check gas supply, flow regulator

and gas hoses.

2. Check gun connection to

machine for obstruction or leaky
seals.

RECOMMENDED
COURSE OF ACTION

If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service
Facility.

GAS FLOW PROBLEMS