MAINTENANCE

D-1

POWER MIG (140, 180 MODELS)

MAINTENANCE

SAFETY PRECAUTIONS

ELECTRIC SHOCK can kill.

• Disconnect input power by removing

plug from receptacle before working
inside POWER MIG (140, 180 MODELS).
Use only grounded receptacle. Do not
touch electrically “hot” parts inside
POWER MIG (140, 180 MODELS).

• Have qualified personnel do the mainte-

nance and trouble shooting work.

---------------------------------------------------------------------------------

ROUTINE MAINTENANCE

POWER SOURCE COMPARTMENT

No user serviceable parts inside! Do not attempt to perform
service in the power source (fixed) side of the POWER MIG
(140, 180 MODELS). Take the unit to an authorized Lincoln
Service Center if you experience problems. NO maintenance
is required.

In extremely dusty locations, dirt may clog the air passages
causing the welder to run hot with premature tripping of ther-
mal protection. If so, blow dirt out of the welder with low pres-
sure air at regular intervals to eliminate excessive dirt and dust
build-up on internal parts.

WIRE FEED COMPARTMENT

1. When necessary, vacuum accumulated dirt from gearbox

and wire feed section.

2. Occasionally inspect the wire guides and keep grooves

clean.

3. Motor and gearbox have lifetime lubrication and require no

maintenance.

FAN MOTOR

Has lifetime lubrication — requires no maintenance.

WIRE REEL SPINDLE

Requires no maintenance. Do not lubricate shaft.