Hired-Hand RS-300 Door: Conversion from Manual Drive to Manaras Operator User Manual
Conversion from manual drive to manaras operator, Warning, Rs 300 door
Conversion from Manual Drive
to Manaras Operator
RS 300 Door
ROLLSEAL, INC. • 1751 Co Rd 68 • Bremen, Alabama 35033 • Phone 256-287-7000 • Fax 256-287-7010
Manual Part No. 4801-5325 Rev 8-05
Page 1
of 2
WARNING
Wiring and Connections Must Comply With All National
And Local Electrical Codes. Installation By Qualified
Electrician Required!
INSTRUCTIONS:
1. Disconnect
electrical
power to RS-300 Door.
2. Remove cover from door. Refer to Figure 1.
3. Remove
curtain
panel.
4. Remove the Chain Guide Wheel and Chain Guide Bracket
from the End Bracket and remove Drive Pipe.
5. Drill out the pop-rivets holding the Drive Shaft into the
Drive Pipe. See Figure 3, Detail A.
6. Remove the lock pin holding the Drive Collar to the Drive
Shaft.
7. Slide the Drive Collar down the Drive Shaft to the end
position as shown in Figure 3, Detail B.
WARNING
Disconnect All Electrical Power Sources to RS-300 Door
Before Installation of Replacement Motor!
8. Insert the Lock Pin through the Drive Collar.
9. Insert the Drive Shaft into the Drive Pipe, align the four
holes in the pipe and fasten with four pop-rivets as Shown
in Figure 3, Detail B.
!
FIG. 1
Exploded View
of Top Assembly
Cover
Manual Drive
(3017-8000)
Curtain panel
End Bracket
Chain Guide Wheel
Chain
Drive Pipe
FIG. 2
Exploded View
Manual Drive
!
FIG. 3
Exploded View
Drive Shaft
Drive Pipe
Pop-Rivet
Drive Shaft
Drive Collar
Detail A
Detail B
Pop-Rivets
Chain Guide Bracket
Chain Keeper
Bushing
(0406-4747)
¼x20x5/8 Screw
(1004-6021)
Lock Nut
(1001-1446)
Washer
(1003-2601)
Bolt
(1004-7077)
Lock Pin
Lock Pin