INSTRUCTIONS:
1. Disconnect
electrical
power to RS 300 Door.
2. Remove Cover from Door by removing tek screws with a 3/8" nut driver. Refer to Figure 1.
3. Remove curtain panel.
4. Remove Top Bar.
5. Unclip Tube Motor from End Plate Bearing in the
Enclosure Assembly.
6. Remove End Bracket from Enclosure Assembly by
removing three ¼" nuts in Back Flange.
7. Slide Tube Motor out of Drive Pipe as shown in Figure 2.
8. Cut 1 5/8" off the Drive Pipe from the end the Tube Motor was removed. See Figure 2.
Conversion From Tube Motor
To Manual Chain Drive
RS 300 Door
WARNING
Wiring And Connections Must Comply With All National
And Local Electrical Codes. Installation By Qualified
Electrician Required!
WARNING
Disconnect All Electrical Power Sources To RS 300 Door
Before Installation Of Replacement Motor!
!
!
Figure 2
Drive Pipe
Cut 1 5/8"
Figure 1
Exploded View Of Top
Assembly
Cover
Right Track
Top Bar
Back Plate
Drive Pipe
Somfy Tube Motor
End Bracket
Enclosure
Assembly
Enclosure
Cover