Connecting to two stages, Connection to powertrak, Ac power – Hired-Hand PowerTrak: Three Wire PVR-2 User Manual
Page 3: Actuator

*Connecting to Two Stages
For Proper Operation:
The Electro-Mechanical Control must contain an internal run timer. Otherwise,
the sidewall / inlet will run continuously.
*Note:
If using this configuration, an electromechanical control
box with an internal timer is recommended. Otherwise,
the sidewall / inlet will run continuously.
AUX
SWITCH
CONTROLLER
AC IN
HOT
NEUT.
LOWER
GND.
HOT
OUT
CLOSE
IN
OPEN
IN
COM
UPPER
120
VAC
GND
OPEN
AC POWER
SIGNAL
CONTROL
NUET
HOT
COM
CLOSE
ACTUATOR
CLOSE
OPEN
COM
1
2
3
4
5
6
7
8
9
120
VAC
GND
OPEN
AC POWER
SIGNAL
CONTROL
NUET
HOT
COM
CLOSE
ACTUATOR
CLOSE
OPEN
COM
1
2
3
4
5
6
7
8
9
120
VAC
STAGE IN
STAGE OUT
STAGE OUT
STAGE IN
}
}
HEAT STAGE
COOL STAGE
*Connection To PowerTrak
*Note:
This is the proper connection if the vent / sidewall opens
while the load block is moving upward. If the opposite is
needed, reverse the connection of open (8) and close (9)
on the actuator portion of the terminal block.
2
- Polar Cool: Portable Evaporative Cooling System (22 pages)
- Polar Cool: External Control Box (4 pages)
- Polar Cool: Pump & Float Replacement (2 pages)
- Polar Cool: PUMP REPLACEMENT (4 pages)
- Polar Cool: Wall Mount Kit (4 pages)
- Unitized Mega Cool (68 pages)
- Unitized Mega Cool: Square Bottom (63 pages)
- Mega-Cool: Square Reservoir (24 pages)
- Mega-Cool rev 6-09 (46 pages)
- Mega-Cool: Mega-Cool Pad Extender Kit (5 pages)
- Mega-Cool: Float Valve Replacement (1 page)
- Mega-Cool: Float Valve (Topaz) Replacement (1 page)
- Mega-Cool: In-Line Pump Motor Replacement (2 pages)
- Var-O-Matic (2 pages)
- System 1000 Power Vent (31 pages)
- System 1000 Power Vent (13 pages)
- System 500 Programs (Conventional Model) (5 pages)
- System 100 Variable Speed Controller (7 pages)
- System 500 Programs (Tunnel Model) (7 pages)
- System 1000 Power Curtain (17 pages)
- System 2000 AUTO TEMP (10 pages)
- System 2001 Power Curtain Controller (43 pages)
- System 500 Power Curtain Controller (31 pages)
- System 1000 Power Curtain Eight Stage Controller (34 pages)
- ICS-500 Environmental Controller (34 pages)
- Pressure Transducer Changeout (1 page)
- HH Software: HH.Net Router/Repeater (8 pages)
- HH Software: 900SS Wireless Network (10 pages)
- HH Software: Farm Manager (22 pages)
- HH Software: Data Shuttle Launch Pad (25 pages)
- Sens-O-Matic (Feed Hopper Switch) (2 pages)
- Manual Light Dimmer (2 pages)
- Electro Mechanical Controls (Relay-Switches): PHOTOHELIC POWER VENT (10 pages)
- Electro Mechanical Controls (Relay-Switches): PT Controller (9 pages)
- Electro Mechanical Controls (Relay-Switches): PC-DB Curtain Controller with DIF (6 pages)
- Electro Mechanical Controls (Relay-Switches): PC-DB Curtain Controller with Timer Override (7 pages)
- Electro Mechanical Controls (Relay-Switches): Photohelic Gauge (1 page)
- Feed Management System (15 pages)
- Contactor Control System (CCS): 4, 8, or 12 Stage (19 pages)
- Contactor Control System (CCS): Triple Pole 16-Stage (7 pages)
- Contactor Control System (CCS): Vent Machine Override 3 Wire PowerTrak (1 page)
- Evolution 4000 Control System (86 pages)
- Evolution Series 1200: Variable Output With Override Pot (14 pages)
- Evolution Series 1200: Variable Output (12 pages)
- Evolution Series 1200 (64 pages)