Part No. 4801-1201 Rev. 8-99 Alert Alarm III 5

red siren wire must be connected into the siren red terminal block position and the same for the
white wire. Note also, any 12VDC device which uses less that 1 amp of current could be connected
in the siren’s place.

7.4 Recommendations

(1) It is recommended that any sensor wire that goes from building to building be run underground.

(2) In any situation where the alarm is used to monitor areas that utilize separate power systems,
relays should be used to inform the controller of a power outage. This could be accomplished via
an auxiliary system and relays or by serializing relays to the power cord of the controller itself.

(3) Use a relay with a 12VDC coil and a separate battery/charging system for any installation where
the siren must be fifty feet or more from the controller.