Hired-Hand Mega Flow SlantWall Fans: METAL CONE Installation Rev 2-09 User Manual
Mega-flow metal cone, Warning, Installation

HIRED-HAND MFG., INC.
• 1733 County Road 68 • Bremen, Alabama 35033 • Phone 256-287-1000 • Fax 256-287-2000
Manual Part No. 4801-5180 Rev 2-09 Page
1
of
2
Arrange panels for assembly
with pilot hole on each panel
facing upward.
Slot for mounting top of
cone to fan housing
Joints
Install #14 x 1/2" sm
screw
Install #14 x 1/2" sm
screw
Pilot hole faces upward
Pull flanges
together to
align
mounting
holes
Mounting
Hole for
Wire Guard
Packing List For One (1) Unit
Tools Required
Four (4) Cone Sections
Four (4) Corner Brackets
7/16 in. (11 mm) Wrench
Ratchet
One (1) Wire Guard
Eight (8) 5/16"-18 x 5/8 Carriage
Bolts
7/16 in. (11 mm) Socket
Marker or Scribe
Five (5) 1/4"-20 Lock Nuts
Ten (10) #14 x 1/2" SIM Screws
Cordless drill and bit (For Installing TEK screws)
Four (4) ¼"-20 x 3/4" Truss
Head Bolts
One (1) Installation Manual
Phillips Head Screwdriver
WARNING!
During Cone Installation Be Sure That Fan Motor Is Not Plugged Into Any Power Source.
Always Double Check Power Sources.
1.
Arrange panels contacting as shown in Figure 1. NOTE: The pilot hole pointing upward. Refer to Figure 1
Inset B.
2.
For each panel, slide panels together. See Figure 1 Inset A.
3.
Align holes of flanges. See Figure 1 Inset A. Install sheet metal screws as shown in Insets B and C.
!
Assembly & Installation of Cone
MEGA-FLOW METAL CONE
Installation
Mounting Holes for
Damper Ring
Figure 1
Inset A
Figure 1
Inset C
Figure 1:
Inset B