beautypg.com

Hired-Hand Circulation and Stir Fans: 52 Orifice Fan HSP Conversion Kit User Manual

Page 2

background image

HIRED-HAND MFG., INC.

• 1733 Co Rd 68 • Bremen, Alabama 35033 • Phone 256-287-1000 • Fax 265-287-2000

Manual Part Number 4802-5150 Rev 3-05

Page 2






13. Attach the motor removed in Step 7 above to the

Top Fan Brace. Note there are two mounting
positions for the motor. Use the UPPER motor
mounting position. See Detail C.
















14. Attach the belt tensioner removed in Step 6

above to the tensioner bracket. Reuse the

existing hardware. See Detail D.

15. Align all pulleys with straight edge. See

Detail E.

16. Install fan belt removed in Step 3 above onto

motor pulley, tension pulley, and prop pulley.

17. Attach the power cable to the motor. Ensure

that the rotating fan blade will not come in contact
with the power cable or the fan frame.

18. Test the fan for proper operation.
19. Installation complete.












DETAIL B

DETAIL D

Install

Tensioner

in mount

Detail C

Lock Nut

Bolt 5/16-18 x ¾”

Belt

NOTE: In this view the Idler Pulley is directly

under the Motor pulley

.

Detail E

Motor pulley

Straight edge

Prop pulley

DANGER!

Do Not Install Fan Within Range Of Human Or Animal Contact!