HATZ Diesel 1B 50 User Manual
Page 78
Type of fault
Possible causes
Remedy
Chapter
The machine is not
uncoupled.
If possible, sepa-
rate the engine
from the machine
by uncoupling it.
Pre glow system is
faulty (additional
equipment)
Contact the HATZ
service station.
Fuel gelled due to
insufficient cold re-
sistance.
Check whether the
fuel that emerges
from the detached
fuel feed line di-
rectly at the injec-
tion pump is clear
and not cloudy. If
the fuel has gelled,
either warm the en-
gine or drain the
entire fuel supply
system. Fill with a
temperature-resist-
ance fuel mixture.
4.2 Fuel,
page 24
7.6 Refuel-
ing, page 40
8.2.11
Changing
the fuel fil-
ter, page 68
Starting speed be-
low 400 rpm :
▪ Oil too viscous.
Change the engine
oil and add oil of
the right viscosity
class.
7.8 Check-
ing the oil
level and
adding oil if
necessary,
page 44
▪ Insufficiently
charged battery.
Check the battery
and contact the
service center if
necessary.
3.2.4 Elec-
trical equip-
ment,
page 18
When equipped
with a stop magnet
or an automatic
electrical switch-off
mechanism (addi-
tional equipment)
The stop magnet is
not functional
and/or irregularities
in the electrical
equipment.
Contact the HATZ
service station.
The engine starts
but then fails to
continue running.
The speed control
lever is not suffi-
ciently set to the
Start direction.
Set the lever to the
Start position.
7.4 Starting
the engine,
page 32
Faults
1B20, 1B27, 1B30, 1B40, 1B50
78
Operator's Manual 1B20-1B50
HATZ