Automatic electrical switch-off with fault storage
This is identified by brief flashing of all indicators after the starting key is
turned to position "I".
NOTICE
i
If the engine stops again immediately after starting, or stops in-
dependently during operation, this is an indication that a moni-
toring element of the automatic shutoff has been activated.
Procedure
Step
Activity
1
Check the indicators (2-4).
After the engine comes to a standstill, the fault will continue to
be displayed by the indicator for approx. another 2 minutes.
2
Then the electrical equipment switches off automatically.
3
Set the starting key to position "0".
4
Turn the starting key back to position "I".
The fault display lights up again.
Remedy the fault before further starting attempts (see the
chapter 9 Faults, page 77).
The indicator goes out at the next start.
7.6
Refueling
Safety notes
DANGER
Fire hazard from fuel.
Leaked or spilled fuel can ignite on hot engine parts and cause
serious burn injuries.
▪ Only refuel while the engine is switched off.
▪ Never refuel in the vicinity of open flames or sparks that can
cause ignition.
▪ Do not smoke.
▪ Do not spill fuel.