beautypg.com

O.50 – Davey SP800-20,30 Single/3 phase SPAPOWER CONTROLLER User Manual

Page 9

background image

Page 26

8. ADV. OPTIONS

- - - -

(SUBMENU)

( )

( )

(ESC)

( )

( )

- - - -

ADV OPTIONS

Push 8

1. HEAT CONTROL
2. FILT. PERIOD*
3. FILT. TIME*

(SET)

( )

( )

O.50

1. HEAT CONTROL

Scroll to SET

1. SET TEMP
2. USER TIMER
3. CLOCK
4. USER ALARM
5. SLEEP TIMES
6. MAINT TIMERS
7. MISC OPTIONS
8. ADV. OPTIONS
9. LD. DEFAULTS

*N/A circulation pump installations

Select MAIN menu then push UP button eight times

7.8.7 Panel And Pool Light Synchronisation (on/off)

The SP800 touch pad backlight has the ability to mirror the colour and intensity of the in-pool Spa Power Variable
Colour Light (SPVCL). This feature is most noticeable when a light effect mode is being used and the light colour is
changing rapidly.

When the pool light is turned off the touch pad backlight will remain one user selectable fixed colour. If desired the
synchronising/mirroring feature can be disabled and the touch pad backlight will remain on the fixed colour even
when the pool light is turned on.

7.8.8 Enabling/Disabling Light Synchronisation

1) Select the MISC OPTIONS submenu from the main menu.
2) Select the PANEL & POOL LT. SYNC menu item
3) Press the SCROLL button modify light synchronisation setting
4) Use the UP and DOWN buttons to toggle between on and off
5) Press the SCROLL button to set.

Note: This option is only available if a SPVCL (Spa Power Variable Colour Light) is in the pool.

7.9 Advanced Options Submenu

The advanced options menu contains settings that should only be modified after you are familiar with the basic
operation of the spa. The defaults will generally be satisfactory and will probably not need to be changed.

Push 1

(Pump On)

Push 2

(Pump Off)

Push 3

(Pump Auto)

Push 1

(Pump On)

Push 2

(Pump Off)

Push 1

(Pump On)

Push 2

(Pump Off)

Page 7

Notes:
1) If Pump 1B is left on, this pump will automatically switch off after 25 minutes.
2) If the heater element is on, running pump may cause the heater to load shed and switch off. If this occurs the

heater will come back on approximately 5 seconds after pump is deselected.

LCD displays “PUMP OFF”, button LEDs off. The Hi/Low speed button has no effect in this mode.

LCD displays “PUMP ON”, button and Auto LEDs green.

LCD displays “PUMP OFF”, button and Auto LEDs off.

LCD displays “PUMP AUTO”, button and Auto LEDs green.

Notes:
1) If Pump 1A is left in”PUMP ON or PUMP OFF, this pump will automatically revert to “PUMP AUTO” mode after 90

minutes.

Two pushes of the Pump 1B button cycles the pump as follows:

LCD displays “PUMP ON”, button LED green.

LCD displays “PUMP OFF”, button LED off.

3.4 Pump 1A & 1B

(Single speed pumps, no 24hr circulation pump fitted)

Two pushes of the on/off button cycles the pump as follows:

This pump is controlled via two touch pad buttons one to turn the pump on/off and another to change its speed. The
mode and pump speed selected by these buttons are shown for a few seconds on the LCD display as well as being
indicated by the pump button LEDs. The two pump button LEDs are green, red or off when the pump is on-low, on-
high or off.

3.3 Pump 1

(Two speed, 24HR circulation pump fitted)

Three pushes of the Pump 1A button cycles the pump as follows:

Push 1

(Pump Hi)

Push 2

(Pump Low)

The Hi/Low speed button can be used to change the pump speed: