INTRODUCTION
The installation of this product should be carried out by a person
knowledgeable in swimming pool plumbing requirements following
the
Inst
allation
Inst
ructions
provided in
this
manual. Please
pass
these instructions on to the owner of this equipment.
– 2 –
Your Davey Cartridge Filter
Congratulations on your purchase of a quality product from the Davey range
of Pool and Spa Equipment. You are assured of many years of reliable and
efficient performance from your Davey Filter backed by Davey’s 5 year tank
guarantee.*
Davey Easy Clear™ Cartridge Filters have been specifically designed for
the filtration of spa and swimming pool water. They should not be used for
any other purpose without first consulting your Davey Dealer or Davey Cus-
tomer Service Centre.
Davey Cartridge Filters provide economy, high performance and conve-
nience in a well-designed pressure filter. The polyester element can be re-
moved quickly for rinse cleaning without water loss. Davey Cartridge Filters
feature large filter areas which ensure even water distribution, peak filtration
performance and longer filter cycles.
The corrosion-resistant construction of Davey Cartridge Filters provides
long-life and durability. Davey Cartridge Filters are capacity matched with
Davey pool pumps forming a total pool filtration system that lasts and lasts.
Davey Cartridge Filters are also very suitable for use with other pool pumps.
Take care to match the pump and filter capacities to gain maximum perfor-
mance and efficiency.
The Sparkling Clear Water Difference
Cartridge filtration is an effective trouble-free proven method of filtration.
Pool water enters the filter and passes through a polyester element car-
tridge. Suspended particles are trapped and the water is returned to the
pool. As the build-up of dirt in the element increases, so the water pressure
rises and the flow decreases. When the pressure reaches an unacceptable
level, the element must be removed and cleaned. (Spray washing with a
common garden hose is generally sufficient).
* Refer to guarantee statement for full details
Installation and Operating Instructions Location
The filter should be placed in its permanent location, preferably as close to
the pool as practicable. Position the filter tank and pump on a level concrete
slab or similar base. Allow sufficient space around the filter for routine main-
tenance and provide for adequate ventilation and drainage.
Place the pump in position on the slab and locate the filter alongside with
the appropriate pump inlet connection oriented towards the pump. Refer to
the specification section for the minimum clearance measurements required
for each model.
– 3 –
Weather Protection
Davey Cartridge Filters are constructed of corrosion resistant materials.
However, to ensure years of reliable performance, it is recommended that
the filtration system is adequately protected from the weather.
Assembly
Assemble the pressure gauge to the filter lid using Teflon tape on the male
thread. Do not over-tighten.
Pipe Connections
Piping should be independently supported and not impose heavy loads on
the filter or pump. Use 40mm or 50mm pipe for pump and pool return lines.
50mm should always be used if length of piping is over 15m.
If the pump and filter are located below pool water level, it is necessary to
fit isolating valves in the pipe between the pump and the pool, and in the
return line from the filter to the pool.
1. Pump to the Filter
Davey Cartridge Filters are equipped with two inlet ports marked ‘INLET’.
Select the inlet port most suitable for the installation and plug the other
inlet port with the blanking cap provided. Using quick connect couplings,
connect the pool pump delivery piping to the selected inlet port. Tighten by
hand only. Ensure the oring on the fitting is clean, lubricated with oring lu-
bricant and in the correct position.
2. Filter to Pool Return
Using quick connect couplings, connect the pool return piping to the filter
fitting marked ‘OUTLET’. Tighten the fitting by hand only. Ensure the oring
on the fitting is clean, lubricated with oring lubricant and in the correct posi-
tion.
The filter base is provided with four mounting holes to enable it to be se-
cured, if required.
Barrel unions need to be hand tightened on. No sealant, glues or
silicones are required.
Davey
®
Repair or Replacement Guarantee
In the unlikely event in Australia or New Zealand that this Davey product develops any malfunction within warranty
periods beginning from the date of original pur
chase due to faulty materials or manufacture, Davey will at our option
repair or r
eplace it for you free of char
ge, subject to the conditions below.
Should you experience any difficulties with your Davey product, we suggest in the first instance that you contact
the Davey Dealer from which you pur
chased the Davey product. Alter
natively you can phone our Customer Service
line on 1300 367 866 in Australia, or 0800 654 333 in New Zealand, or send a written letter to Davey at the address
listed below. On r
eceipt of your claim, Davey will seek to resolve your difficulties or
, if the product is faulty or
defective, advise you on how to have your Davey product r
epaired, obtain a r
eplacement or a refund.
Your Davey Guarantee naturally does not cover normal wear or tear
, replacement of pr
oduct consumables (i.e.
mechanical seals, bearings or capacitors), loss or damage resulting fr
om misuse or negligent handling, improper
use for which the product was not designed or advertised, failur
e to properly follow the pr
ovided installation and
operating instructions, failure to carry out maintenance, corr
osive or abrasive water or other liquid, lightning or high
voltage spikes, or unauthorized persons attempting repairs. Wher
e applicable, your Davey product must only be
connected to the voltage shown on the nameplate.
Your Davey Guarantee does not cover fr
eight or any other costs incurred in making a claim. Please r
etain your
receipt as pr
oof of purchase; you
MUST pr
ovide evidence of the date of original purchase when claiming under the
Davey Guarantee.
Davey shall not be liable for any loss of profits or any consequential, indir
ect or special loss, damage or injury of
any kind whatsoever arising directly or indir
ectly from Davey pr
oducts. This limitation does not apply to any liability
of Davey for failure to comply with a consumer guarantee applicable to your Davey
product under the Australian
or New Zealand legislation and does not affect any rights or r
emedies that may be available to you under the
Australian or New Zealand Consumer Legislation.
In Australia, you are entitled to a r
eplacement or refund for a major failur
e and for compensation for any other
reasonably for
eseeable loss or damage. You ar
e also entitled to have the goods repair
ed or replaced if the goods fail
to be of acceptable quality and the failure does not amount to a major failur
e.
Should your Davey product r
equire r
epair or service after the guarantee period; contact your nearest Davey Dealer
or phone the Davey Customer Service Centre on the number listed below
.
For a complete list of Davey Dealers visit our website (davey.com.au) or call:
* Installation and operating instructions ar
e included with the product when pur
chased new.
They may also be found on our website.
P/N 48521-6 supersedes P/N 48521-5
AUSTRALIA
Customer Service Centre
6 Lakeview Drive,
Scoresby
, Australia 3179
Ph:
1300 367 866
Fax:
1300 369 119
Website:
davey
.com.au
Davey Water Pr
oducts Pty Ltd
Member of the GUD Group
ABN 18 066 327 517
NEW ZEALAND
Customer Service Centre
7 Rockridge Avenue,
Penrose, Auckland 1061
Ph:
0800 654 333
Fax:
09 527 7654
Website:
daveynz.co.nz
® Davey & Easy Clear are r
egistered trade marks of Davey W
ater Products Pty Ltd.
© Davey Water Pr
oducts Pty Ltd 2011.
Davey Guarantee Period
Tank - Five Y
ears Other Components - One Year