Brocade Network Advisor SMI Agent Developers Guide v12.3.0 User Manual
Page 144
![background image](/manuals/361715/144/background.png)
128
Brocade Network Advisor SMI Agent Developer’s Guide
53-1003159-01
Alert indications
4
BRCD51
Successful recovery from a faulty
condition.
Query: SELECT * FROM
CIM_AlertIndication WHERE
OwningEntity=BROCADE and
MessageID=BRCD51
NOTE: BRCD51 indication is supported
for the Environment, Port, and
E_Port Fabric Watch classes.
Ignore the Fabric Watch
indications for non-supported
Fabric Watch classes (GBIC or
SFP, Fabric, F and FL Port, SAM,
Security), as they are not
supported.
BRCD51 is supported in switches
running Fabric OS v6.1.0 and
later.
AlertingManagedElement
COP of Brocade_Switch
AlertingElementFormat
COP
AlertType
Other Alert
OtherAlertType
Fabric Watch
AlertSubType
Threshold In Between
PerceivedSeverity
2 (Informational)
ProbableCause
123
SystemCreationClassName
Brocade_Switch
SystemName
Fabric WWN
ProviderName
Brocade_AlertIndication
Provider
OwningEntity
BROCADE
Message
Fabric Watch Threshold
In Between
MessageArguments
N/A
BRCD52
A counter value between two sample
periods has changed.
Query: SELECT * FROM
CIM_AlertIndication WHERE
OwningEntity=BROCADE and
MessageID=BRCD52
NOTE: BRCD52 indication is supported
for the Environment, Port, and
E_Port Fabric Watch classes.
Ignore the Fabric Watch
indications for non-supported
Fabric Watch classes (GBIC or
SFP, Fabric, F/FL Port, SAM,
Security), as they are not
supported.
BRCD52 is supported in switches
running Fabric OS v6.1.0 and
later.
AlertingManagedElement
COP of Brocade_Switch
AlertingElementFormat
COP
AlertType
Other Alert
OtherAlertType
Fabric Watch
AlertSubType
Threshold Change
PerceivedSeverity
2 (Informational)
ProbableCause
123
SystemCreationClassName
Brocade_Switch
SystemName
Switch WWN
ProviderName
Brocade_AlertIndication
Provider
OwningEntity
BROCADE
Message
Fabric Watch Threshold
Changed
MessageArguments
N/A
TABLE 14
Supported alert indications (Continued)
Message ID
Trigger
Property
Value