Brocade Network Advisor SMI Agent Developers Guide v12.3.0 User Manual
Page 123
![background image](/manuals/361715/123/background.png)
Brocade Network Advisor SMI Agent Developer’s Guide
107
53-1003159-01
Alert indications
4
FC2
Configuration was enabled, and now this
configuration is the active configuration.
Query: SELECT * FROM
CIM_AlertIndication WHERE
OwningEntity=SNIA and MessageID=FC2
How to trigger: Enable the zoning
configuration. You can also do this
through the CLIs zonadd, cfgsave, and
cfgenable.
AlertingManagedElement
COP of Brocade_Fabric
AlertingElementFormat
COP
AlertType
Device Alert
OtherAlertType
N/A
AlertSubType
Config Enabled
PerceivedSeverity
5 (Major)
ProbableCause
123
SystemCreationClassName
Brocade_Fabric
SystemName
Fabric WWN
ProviderName
Brocade_AlertIndication
Provider
OwningEntity
SNIA
Message
ZoneSet
fabric
MessageArguments
ZoneSet name Fabric
WWN
FC5
Change in operational status for switch.
Query: SELECT * FROM
CIM_AlertIndication WHERE
OwningEntity=SNIA and MessageID=FC5
AlertingManagedElement
COP of Brocade_Switch
AlertingElementFormat
COP
AlertType
Device Alert
OtherAlertType
N/A
AlertSubType
Switch modified
PerceivedSeverity
5 (Major)
ProbableCause
123
SystemCreationClassName
Brocade_Switch
SystemName
Switch WWN
ProviderName
Brocade_AlertIndication
Provider
OwningEntity
SNIA
Message
Switch
changed to
MessageArguments
Switch WWN, fabric
WWN, switch operational
status
TABLE 14
Supported alert indications (Continued)
Message ID
Trigger
Property
Value