Brocade Network Advisor SMI Agent Developers Guide v12.3.0 User Manual
Page 126
110
Brocade Network Advisor SMI Agent Developer’s Guide
53-1003159-01
Alert indications
4
Core6
Switch login was attempted.
Query: SELECT * FROM
CIM_AlertIndication WHERE
OwningEntity=SNIA and
MessageID=Core6
How to trigger: Telnet to the switch.
NOTE: Core6 indication is supported only
for FOS switches. This indication
is not delivered if SNMP
registration fails.
Core6 indications are delivered
when trackChangeset and SNMP
forward options are enabled in
switch.
AlertingManagedElement
COP of Brocade_Switch
AlertingElementFormat
COP
AlertType
Security
OtherAlertType
N/A
AlertSubType
New Login
PerceivedSeverity
Informational
ProbableCause
123
SystemCreationClassName
Brocade_Switch
SystemName
Switch WWN
ProviderName
Brocade_AlertIndication
Provider
OwningEntity
SNIA
Message
MessageArguments
Device Type = Switch;
Unique Identifier = WWN;
User = UserName;
Login Operation = logged
in
TABLE 14
Supported alert indications (Continued)
Message ID
Trigger
Property
Value