Brocade Network Advisor SMI Agent Developers Guide v12.3.0 User Manual
Page 129
![background image](/manuals/361715/129/background.png)
Brocade Network Advisor SMI Agent Developer’s Guide
113
53-1003159-01
Alert indications
4
BRCD4
Configuration changed
Query: SELECT * FROM
CIM_AlertIndication WHERE
OwningEntity=BROCADE and
MessageID=BRCD4
How to trigger: Perform the CLI
configdownload to the switch.
NOTE: BRCD4 Indication is a switch Alert
indication and it is applicable only
to FOS switches. This indication is
not delivered if SNMP registration
is failed.
AlertingManagedElement
COP of Brocade_Switch
AlertingElementFormat
COP
AlertType
Other
OtherAlertType
Switch Alert
AlertSubType
Config Change
PerceivedSeverity
2 (Informational)
ProbableCause
123
SystemCreationClassName
Brocade_Switch
SystemName
Switch WWN
ProviderName
Brocade_AlertIndication
Provider
OwningEntity
BROCADE
Message
Configuration changed
for Switch
MessageArguments
WWN = stringSwitch
WWN
BRDC5
SNMP traps were turned on to alert user
login and logout attempts.
Query: SELECT * FROM
CIM_AlertIndication WHERE
OwningEntity=BROCADE and
MessageID=BRCD5
How to trigger: Use the trackchangesset
CLI command to turn on the SNMP traps.
NOTE: BRCD5 indication is supported
only for FOS switches and is not
delivered if SNMP registration is
failed.
AlertingManagedElement
COP of Brocade_Switch
AlertingElementFormat
COP
AlertType
Other
OtherAlertType
Switch Alert
AlertSubType
Track Change On
PerceivedSeverity
2 (Informational)
ProbableCause
123
SystemCreationClassName
Brocade_Switch
SystemName
Switch WWN
ProviderName
Brocade_AlertIndication
Provider
OwningEntity
BROCADE
Message
Alert configuration for
login, logout or config
updates was turned ON
for Switch
MessageArguments
WWN = string Switch
WWN
TABLE 14
Supported alert indications (Continued)
Message ID
Trigger
Property
Value