Brocade Network Advisor SMI Agent Developers Guide v12.3.0 User Manual
Page 130
114
Brocade Network Advisor SMI Agent Developer’s Guide
53-1003159-01
Alert indications
4
BRDC6
SNMP traps turned on by Track Change
On was turned off.
Query: SELECT * FROM
CIM_AlertIndication WHERE
OwningEntity=BROCADE and
MessageID=BRCD6
How to trigger: Use the trackchangesset
CLI command to turn off the SNMP traps.
NOTE: BRCD6 indication is supported
only for FOS switches and is not
delivered if SNMP registration is
failed.
AlertingManagedElement
COP of Brocade_Switch
AlertingElementFormat
COP
AlertType
Other
OtherAlertType
Switch Alert
AlertSubType
Track Change Off
PerceivedSeverity
2 (Informational)
ProbableCause
123
SystemCreationClassName
Brocade_Switch
SystemName
Switch WWN
ProviderName
Brocade_AlertIndication
Provider
OwningEntity
BROCADE
Message
Alert configuration for
login, logout, orconfig
updates was turned OFF
for Switch
MessageArguments
WWN = string Switch
WWN
BRCD7
The element (port) identified by
AlertingManagedElement is up.
Query: SELECT * FROM
CIM_AlertIndication WHERE
OwningEntity=SNIA and
MessageID=BRCD7
How to trigger: Telnet to the switch and
run the CLI portenable portnumber to
enable a connected port, such as an
E_Port, F_Port, or L_Port.
AlertingManagedElement
COP of
Brocade_SwitchFCPort
AlertingElementFormat
COP
AlertType
Other
OtherAlertType
Port Alert
AlertSubType
Up
PerceivedSeverity
2 (Informational)
ProbableCause
123
SystemCreationClassName
Brocade_Switch
SystemName
Switch WWN
ProviderName
Brocade_AlertIndication
Provider
OwningEntity
BROCADE
Message
Port
Switch
up
MessageArguments
SwitchFCPort WWN
Switch WWN
TABLE 14
Supported alert indications (Continued)
Message ID
Trigger
Property
Value