Verifying the installation – Brocade Mobility RFS4000 Controller Installation Guide (Supporting software release 4.3.0.0 and later) User Manual
Page 34

Verifying the installation
4
24
Brocade Mobility RFS4000 Controller Installation Guide
53-1001933-02
CAUTION
Using the switch reset button will reset all configuration information
and settings on the switch to factory defaults. All previously configured
information and settings will be lost. The country code will need to be
set when the switch is rebooted before any access ports or adaptive
APs will be adopted.
Verifying the installation
View the LEDs on the front panel of the Brocade Mobility RFS4000 Controller to
ensure the device is functioning properly. The normal LED pattern follows this path:
•
During the Power On Self Test (POST), the System 1 and System 2 LEDs both
blink green.
•
If the POST test fails, the System 1 LED will blink amber. If the POST test
succeeds, the System 1 LED will be lit solid green.
•
As the software is initialized, the System 2 LED will blink green.
After the software has finished initializing, the System 1 LED will be lit solid green
and the bottom System 2 LED will be off. The Brocade Mobility RFS4000 Controller
is ready to be configured, as described in the Brocade Mobility RFS4000, RFS6000
and RFS7000 System Reference Guide available from the Brocade website at
http://www.brocade.com/support/
.
Other LED codes indicate the presence (or absence) of different standby states, or
errors. A guide to the Brocade Mobility RFS4000 Controller LED codes is provided in
.
MobilityRFS4000ControllerInstallGuide.book Page 24 Friday, June 10, 2011 1:32 PM