Port Side LED patterns during normal operation
TABLE 4
LED Name
LED Color
Status of Hardware
Recommended Action
Power Status
No light
System is off or there is an
internal power supply failure.
Verify that system is powered on (power
supply switches to "1"), the power cables
attached, and your power source is live.
If the system power LED is not green, the
unit may be faulty.
Contact your Extension Switch service
provider.
Steady green
System is on and power
supplies are functioning
properly.
No action required.
System Status
No light
System is off or there is no
power.
Verify that system is on and has completed
booting.
Steady green
System is on and functioning
properly.
No action required.
Steady amber
(for more than
five seconds)
Unknown state, boot failed, or
the system is faulty.
This LED displays steady
amber during POST; this is
normal and does not indicate
a fault.
Perform the following steps:
1. Connect a serial cable to the system.
2. Reboot the system.
3. Check the failure indicated on the system
console
4. Contact your Extension Switch service
provider.
Flashing amber/
green
Attention is required. A
number of variables can
cause this status including a
single power supply failure, a
fan failure, or one or more
environmental ranges has
exceeded.
Check the management interface and the
error log for details on the cause of status.
Contact your Extension Switch service
provider.
Ethernet Link
No light
There is no link.
Verify that the Ethernet cable is connected
correctly.
Steady green
There is a link
No action required.
Ethernet Status/
Activity
No light
No activity
No action required.
Flashing green
There is link activity (traffic).
No action required.
FC Port Status
No light
Indicates one of the following:
• No signal or light carrier
(media or cable) detected.
• Blade may be currently
initializing.
• Connected device is
configured in an offline
state.
• Verify the power LED is on, and check
the SFP and cable.
• Verify the blade is not currently being
initialized.
• Verify the status of the connected device.
Operating the Brocade 7800 Extension Switch
Brocade 7800 Extension Switch Hardware Reference Manual
35