Installing and configuring the Brocade 7800
Setting up the Brocade 7800 Extension Switch as a standalone unit............................. 22
Installation and safety considerations
You can install the Brocade 7800 in the following ways:
• As a standalone unit on a flat surface.
• In an EIA rack using the fixed rack mount kit, slide rack mount kit, or the mid-mount rack kit.
To install and operate the Brocade 7800 successfully, ensure that the following requirements are met:
• The primary AC input is 100-240 VAC (Brocade 7800 autosenses input voltage), 47-63 Hz.200-240
VAC is recommended.
• The primary outlet is correctly wired, protected by a circuit breaker, and grounded in accordance with
local electrical codes.
• The supply circuit, line fusing, and wire size are adequate, as specified by the electrical rating on the
Brocade 7800 nameplate.
For power supply information, see
on page 46 .
To ensure adequate cooling, install the Brocade 7800 with the nonport side, which contains the air
intake vents, facing a cool-air aisle.
CAUTION
Make sure the airflow around the front, sides, and back of the device is not restricted.
Verify that the ambient air temperature does not exceed 400° C (104° F) and that the ambient humidity
remains between 20% and 85% while the Brocade 7800 is operating.
CAUTION
Do not install the device in an environment where the operating ambient temperature might
exceed 40°C (104°F).
If installing the Brocade 7800 in a rack.
• The rack must be a standard EIA rack.
• Plan a rack space that is 1U (1.75 in.; 4.44 cm), 19 in. (48.3 cm) wide, and at least 24 in. (61cm)
deep.
• Ground all equipment in the rack through a reliable branch circuit connection and maintain ground at
all times. Do not rely on a secondary connection to a branch circuit, such as a power strip.
• Ensure that airflow and temperature requirements are met on an ongoing basis.
Brocade 7800 Extension Switch Hardware Reference Manual
19
53-1001350-05