Environmental requirements, General specifications – Brocade 5300 Hardware Reference Manual User Manual
Page 41
Brocade 5300 Hardware Reference Manual
29
53-1000858-04
Environmental requirements
A
Environmental requirements
lists the acceptable environmental ranges for both operating and nonoperating (such as
during transportation or storage) conditions.
General specifications
lists the general specifications for the Brocade 5300.
Nominal system DC power consumption
260 Watts
Input voltage
85-264 VAC
Input line frequency
47-63HZ
BTU rating
1313 BTU/hr
Inrush current
Maximum of 38A for period of 10-150mS
Input line protection
Both AC lines are fused
TABLE 6
Power Supply Specifications
Specification Value
TABLE 7
Environmental requirements
Condition
Acceptable during operation
Acceptable During Non-Operation
Ambient
Temperature
0º to 40º C
32º to 104º F
-25º to 70º C
-13º to 158º F
Humidity
10% to 85% RH non-condensing, at
40º C (104º F), with maximum gradient of 10%
per hour
10% to 90% RH non-condensing, at 70º C
(158º F)
Altitude
0 to 3 km (10,000 feet) above sea level
0 to 12 km (40,000 feet) above sea level
Shock
20 G, 6 ms, half-sine wave
33 G, 11 ms, 3/eg Axis
Vibration
0.5 G, 5-500 Hz
2.0 G, 5-500 Hz
Air flow
High speed 9000 RPM 102 CMH (60 CFM)
Low speed 6000 RPM 74.8 CMH (44 CFM)
None required.
TABLE 8
General specifications
Specification
Description
Configurable port types
F_Port, FL_Port, E_Port, EX_Port, and M_Port
System architecture
Nonblocking shared-memory switch
System processor
Freescale MPC8548 x 1.3GHz
ANSI Fibre Channel protocol
FC-PH (Fibre Channel Physical and Signalling Interface standard)
Modes of operation
Fibre Channel Class 2 and Class 3
Fabric initialization
Complies with FC-SW-3 Rev. 6.6
FC-IP (IP-over-Fibre Channel)
Complies with FC-IP 2.3 of FCA profile