Field replaceable units (frus), Power supplies, Fan assemblies – Brocade 5300 Hardware Reference Manual User Manual
Page 37
Brocade 5300 Hardware Reference Manual
25
53-1000858-04
Brocade 5300 Maintenance
3
Field Replaceable Units (FRUs)
You can replace the power supplies and fan assemblies on site without the use of special tools. The
power supplies and fan assemblies are keyed to ensure correct orientation during installation.
Installation instructions are provided with all replacement units.
Power supplies
The two power supplies are hot-swappable. They are identical and fit into either power supply slot.
Fabric OS identifies the power supplies as follows (viewing the switch from the non-port side):
•
Power supply 1 on the right
•
Power supply 2 on the left
Use one of the following methods to determine if you need to replace a power supply.
•
Check the power supply status LED next to the On/Off switch (see
•
In Web Tools, click the Power Status icon.
•
Enter the psShow command at the prompt to display power supply status as shown below:
For further information on replacing the power supplies, see the Mid-Size Switch Power Supply
Replacement Procedure.
Fan assemblies
The three fan assemblies are hot-swappable. They are identical and fit into any fan assembly slot.
Each fan assembly contains two fans, identified by Fabric OS as follows (viewing the switch from
the non-port side):
•
Fan assembly #1 on the right
•
Fan assembly #2 in the center
•
Fan assembly #3 on the left
Use one of the following methods to determine if you need to replace a fan assembly.
•
Check the fan status LED on the face of the fan assembly (see
•
In Web Tools, click the Fan Status icon.
br5300:admin> psshow
Power Supply #1 is OK
V10529, TQ2H0000030 ,60-0300031-01,X2, ,SP640
,2X,TQ2H0000
Power Supply #2 is OK
V10541, TQ2H0000189 ,60-0300031-01,X3, ,SP640-2P ,A
,TQ2H0000
br5300:admin>