beautypg.com

Size and weight, Environmental requirements – Brocade Encryption Switch Hardware Reference Manual (Supporting Fabric OS v6.1.1_enc) User Manual

Page 47

background image

Brocade Encryption Switch Hardware Reference Manual

33

53-1001117-02

A

Size and weight

Table 3

lists the dimensions and weight of the switch.

Environmental requirements

Table 4

lists the acceptable environmental ranges for operating and nonoperating (such as during

transportation or storage) conditions.

TABLE 3

Physical specifications

Dimension

Value

Height

2U = 86 mm (3.34 inches)

Depth

635 mm (25 inches)

Width

429 mm (16.88 inches)

Weight (with two power supplies; no SFPs)

22.4 kg (49.4 lbs)

TABLE 4

Environmental requirements

Condition

Acceptable During Operation

Acceptable During Non-Operation

Ambient
temperature

0

°

to 40

°

Celsius

(32

°

to 104

°

Fahrenheit)

-25

°

to 70

°

Celsius

(-13

°

to 158

°

Fahrenheit)

Humidity

10% to 85% RH non-condensing, at
40

° Celsius (104

°

Fahrenheit) , with maximum

gradient of 10% per hour

10% to 90% RH non-condensing, at 70°
Celsius (158

°

Fahrenheit)

Altitude

3,000 meters (9,842 feet) above sea level

0 to 12 kilometers (39,370 feet) above sea
level

Shock

20 G, 6 ms, half-sine wave

Half sine, 33 G 11ms, 3/eg Axis

Vibration

0.5 G sine, 0.4 grms random, 5-500 Hz

2.0 G sine, 1.1 grms random 5-500 Hz

Airflow

76 CFM (129/2 cubic meters per hour)
Maximum; 53 CFM (90.1 cubic meters per
hour) Nominal

N/A

Heat dissipation

1183 BTU/hr.

N/A