Brocade Encryption Switch Hardware Reference Manual (Supporting Fabric OS v6.1.1_enc) User Manual
Page 41

Brocade Encryption Switch Hardware Reference Manual
27
53-1001117-02
3
Power supply
status
No light
Indicates one of the following:
•
Power supply FRU is switched
off.
•
Power supply FRU is not seated
correctly.
•
Power cord is disconnected.
•
Power cord is not actively
powered.
•
The power supply FRU has
failed.
Try the following:
•
Verify that the power supply FRU
is powered on.
•
Verify that the power supply FRU
is seated correctly.
•
Check the power cable
connection.
•
Replace the power supply FRU.
Steady green
Power supply is operating normally.
No action required.
Steady amber (for
more than 5
seconds)
Indicates one of the following:
•
Power supply FRU is switched
off.
•
Power supply FRU is not seated
correctly.
•
The power cable is
disconnected.
•
The power supply FRU has
failed.
Note: When the switch is first
powered on the power supply status
LED will show amber until POST has
completed.
Try the following:
•
Verify that the power supply FRU
is powered on.
•
Verify that the power supply FRU
is seated correctly.
•
Check the power cable
connection.
•
Replace the power supply FRU.
Fan status
No light
Indicates one of the following:
•
Fan FRU is not seated correctly.
•
Fan FRU is not receiving power.
Try the following:
•
Verify that the fan FRU is seated
correctly.
•
Verify that the switch is powered
on.
Steady green
Fan assembly is operating normally.
No action required.
Steady amber (for
more than 5
seconds)
Indicates one of the following:
•
Fan FRU is not seated correctly.
•
One or more of the fans in the
fan FRU has failed.
•
The fan FRU was disabled by
the user.
Note: When the switch is first
powered on the fan status LED will
show amber until POST has
completed.
Try the following:
•
Verify that the fan FRU is seated
correctly.
•
Verify that the fan FRU is
enabled (use the fanEnable
command).
•
Replace the fan FRU.
TABLE 2
Switch and FRU LEDs (Continued)
LED Name LED Color
Status of Hardware
Recommended Action