Power supply specifications – Brocade VDX 6740 Hardware Reference Manual (Supporting VDX 6740, VDX 6740T, and VDX 6740T-1G) User Manual
Page 59
Brocade VDX 6740 Hardware Reference Manual
47
53_1002829_02
Power supply specifications
A
Power supply specifications
The power supplies are universal and capable of functioning worldwide without voltage jumpers or
switches. They meet IEC 61000-4-5 surge voltage requirements and are autoranging in terms of
accommodating input voltages and line frequencies.
lists the power supply specifications for the Brocade VDX 6740 switches.
illustrate the power consumption of the switch as measured at maximum
draw.
TABLE 12
Power supply specifications
Specification Value
Input voltage
Range: 90-264 VAC Auto-volt, Nominal: 100-240 VAC, (VDX 6740-3.5A max,
VDX 6740T and VDX 6740T-1G 6.0A max); switch autosenses input voltage
Start-up: 80-87 VAC, Turn-off: 85-75 VAC
Input frequency
Range: 47-63 Hz; Nominal: 50-60 Hz
Inrush current
Brocade VDX 6740 (250 W power supply) - Limited to 50 A peak @ 240 VAC
during cold startup at 25ºC ambient
Brocade VDX 6740T (500 W power supply) - Limited to 30 A peak @ 240 VAC
during cold startup at 25ºC ambient
Input line protection
Both AC lines are fused.
Maximum power supply output
(each)
250 watts @ 12V DC - Brocade VDX 6740
500 watts @ 12V DC - Brocade VDX 6740T
TABLE 13
VDX 6740 power consumption - maximum
MAX: Brocade VDX 6740 All ports configured with ELOAD, Traffic Running (mode 11), Fan Speed Max (8190 RPM), Room
Temp
AC voltage
Input current
(Amp) 1 PSU
Input watts
1 PSU
AC measured
BTU/hr
1 PSU
Input watts
2 PSUs
AC measured
BTU/hr
2 PSUs
100 VAC
1.65
165.00
563.16
170.00
580.22
120 VAC
1.37
165.40
564.52
170.27
581.15
200 VAC
0.85
164.00
559.75
168.45
574.93
240 VAC
0.75
164.00
559.75
168.00
573.40
TABLE 14
VDX 6740T and VDX 6740T-1G power consumption - maximum
MAX: Brocade VDX 6740T All ports configured with ELOAD, Traffic Running (mode 11), Fan Speed Max (8190 RPM), Room
Temp
AC voltage
Input current
(Amp) 1 PSU
Input watts
1 PSU
AC measured
BTU/hr
1 PSU
Input watts
2 PSUs
AC measured
BTU/hr
2 PSUs
100 VAC
4.90
488.00
1665.58
490.00
1672.41
120 VAC
4.53
482.00
1645.10
486.00
1658.76
200 VAC
2.44
474.00
1617.80
480.00
1638.28
240 VAC
2.05
473.00
1614.39
479.00
1634.87