Weight and physical dimensions, Facility requirements – Brocade VDX 6740 Hardware Reference Manual (Supporting VDX 6740, VDX 6740T, and VDX 6740T-1G) User Manual
Page 58

46
Brocade VDX 6740 Hardware Reference Manual
53_1002829_02
Weight and physical dimensions
A
Weight and physical dimensions
lists the weight and dimensions of the Brocade VDX 6740 switches.
Facility requirements
provides the facilities requirements that must be met for the Brocade VDX 6740.
TABLE 10
Physical specifications
Dimension
Value
Height
44.45 mm (1.75 in.) - Brocade VDX 6740
42.67 mm (1.68 in.) - Brocade VDX 6740T and Brocade
VDX 6740T-1G
Depth
409.16 mm (16.14 in.) - Brocade VDX 6740
536.45 mm (21.12 in.) - Brocade VDX 6740T and
Brocade VDX 6740T-1G
Width
439.93 mm (17.32 in.) - Brocade VDX 6740
437.38 mm (17.22 in.) - Brocade VDX 6740T and
Brocade VDX 6740T-1G
Weight (with all power supplies and fan assemblies, and
no transceivers installed)
8.66 kg (19.10 lb) - Brocade VDX 6740
10.82 kg (23.85 lb) - Brocade VDX 6740T and Brocade
VDX 6740T-1G
TABLE 11
Facility requirements
Type
Requirements
Electrical
•
Primary AC input rated 100-240 VAC, operating input range 90-264 VAC (Brocade VDX
6740), 85-264 VAC (Brocade VDX 6740T), 50-60 Hz; switch autosenses input voltage
•
Adequate supply circuit, line fusing, and wire size, as specified by the electrical rating
on the switch nameplate
•
Circuit protected by a circuit breaker and grounded in accordance with local electrical
codes
Refer to
for complete power supply specifications.
Thermal
•
Ambient air temperature not exceeding 40
C (104
F) while the switch is operating
Rack
•
One rack unit (1U) in a 48.3 cm (19-inch) rack - Brocade VDX 6740
•
All equipment in cabinet grounded through a reliable branch circuit connection
•
Additional weight of switch not to exceed the rack’s weight limits
•