background image

PM2L-R

Input / Control Panel

Mute Controls

PM2l-R

Power Control Panel

Power On / Off

AC Power Connecto

r

Powercon locking connector

Overdrive LED

Flashes red when the amplifiers

protective circuitry is engaged

Signal LED

Flickers when an audio signal of at

least -30

dBu is present

Secondary Analog - AES/EBU

Input/Output

Can be configured for “priority

override”

Primary & Secondary

Ethernet Inputs

RJ-45 female;when both

are connected, change-

over to Secondary is

automatic if Primary fails.

Yellow LED flashes when

the connector is active,

glows steadily when data

is streaming. Green LEDs

glow when connected but

inactive, turn Orange to

indicate a faulty connec-

tion.

Primary Analog - AES/

EBU Input/Output &

Looping Output

XLR female; pin 1 chassis,

pin 2 +, pin 3 -

Push Button Volume Controls

Also function as a manual

Standby/On

control

Input Pad & LED Indicator

On / Off 10 dB pad for Primary Analog Input; allows input signals

of up to +24 dBu when inserted. Input Clip LED flashes red

when the Primary Analog Input preamplifier is being overdriven.

AES/EBU Input Switch

When On, turns analog input 1

into an AES/EBU input

Power LED

Glows when amplifier

power is On

Thermal LED

Lights to indicate that an over-

temperature sensor has shut

down the amplifier

Push-To-Reset

Circuit Breakers