beautypg.com

Renkus-Heinz IC2-FR User Manual

Page 27

background image

27

CONNECT

Users Manual

IC

2

Before going on you should first verify that the correct

measurement system is being used (feet or meters).

The default measurement system is feet but you may

want to use meters.

To check or change the setting, right click in the center

of the beam steering window or select Preferences

from the Options pull down menu in the tool bar section

of RHAON window. If you want to change from feet to

meters, click in the Metric radio button.

Note that this window also allows you to control the

behavior of the Fault Relay and the Power-On sequenc-

ing delay.

The Beam Steering tab contains the setting controls

for the appearance of the Beam Steering window. The

normal default setting are shown.

This setup window also allows you to change the height

of the measuring plane (the Ear Height). Until you are

more familiar with the program we suggest you accept

the default setting. There are times, however, when you

will want to change the height of the measuring plane. It

is set to 1.2 meters (3.94 feet) which is fine for a seated

audience, but not for a standing audience. For a stand-

ing audience a height of 5.5 feet is commonly used.

Note that the measuring plane does not show in the

mapping screen. The heavy dark line is the floor level

and not the measuring plane.

The Mapping Appearance section allows you to control

the appearance of the main Mapping plot. For now, we

suggest using the default settings. You can experiment

with various settings later.

The Scale Level Views section gives you control over

the scales used in the main Mapping window. Notice

that you also have the option of disabling (turning off)

the warning messages that pop up in Beam Steering

and the Beam EQ Normalization feature.

Many experienced users like to use the Fixed Range

option under Scale Level Views; setting the Round Up

to 5 and the Show Range to 5. You may want to experi-

ment with this to see which settings you like best. We

used the Fixed Range option for the displays in this manual.

We’ll investigate the other tabs later.