Cont ...

TECHNICAL SPECIFICATION

*Height not inclusive of resilient mounting foot.

Note: For information on other voltages/frequencies which are not shown, consult

any supplementary instruction sheet supplied, or rating label attached to the

pump.

Stuart Turner reserve the right to amend the specification in line with its policy of

continuous development of its products.

Model

Supply

Max. Watts
Consumed

Nominal

Watts

Output

(Motor)

Full

Load

Current
(AMPS)

Enc.

Rating

Duty

Rating

Dims (mm)

Gross

Weight

(packed)

kg

No. of

Pump

Stages

L

W

H*

RGFL4000

230/1/50

350

120

1.5

IP44

Continuous

(S1) @ 2.5 l/min

& above

203

126

202

5.1

1

RGFL6000

230/1/50

540

300

2.4

IP44

203

126

202

5.7

1

RGDFL6000

230/1/50

860

550

3.4

IP44

301

126

201

8.4

1

(twin pump)

ESFL4000

230/1/50

360

120

1.6

IP44

Continuous

(S1) @ 4.5 l/min

& above

232

126

221

5.6

1

ESFL6000

230/1/50

550

300

2.5

IP44

232

126

221

5.9

1

KFL9-2

230/1/50

265

180

1.2

IP44

Continuous 242

133

231

6.5

1

KFL12-2

230/1/50

485

250

2.1

IP44

Continuous 242

133

231

6.7

1

LFL5-4S

230/1/50

925

600

4.1

IP44

Continuous 401

202

307

11.1

4

LFL7-4S

230/1/50

1085

760

5.0

IP44

Continuous 401

202

307

12.5

4

TFL6-2

230/1/50

890

530

3.9

IP44

Continuous 326

210

304

9.9

2

TFL12-2

230/1/50

1155

800

5.3

IP44

Continuous 350

210

304

11.1