Supply Cord Replacement
If the supply cord is to be changed or is damaged, it must be replaced with a special cord
assembly available from Stuart Turner or one of their approved repairers.
On disassembly note the cord retention and routing system. Reassemble to the same
pattern.
For information on cable connection consult the wiring diagram and cable gland fitting
instructions.
Intermediate Connecting Cord Replacement
(Applicable to TFL and LFL ranges only)
These pumps incorporate an additional cord which connects the main terminal box to
the motor terminal box. If this cord is damaged, it must be replaced with a special cord
assembly available from Stuart Turner or one of their approved repairers.
On disassembly note the cord retention and routing system. Reassemble to the same
pattern.
For information on cable connection consult the wiring diagram.
Supply Cord Extension
The pumps are fitted with a supply cord to the following specification:
RGFL, RGDFL, ESFL & KFL range:- . . . . . HO5VV-F3 G 0.75 mm², 6 Amp rating.
LFL & TFL range:- . . . . . . . . . . . . . . . . . . . HO7RN-F3 G 1.0 mm², 10 Amp rating.
If the supply cord is to be extended, a cord of the same specification should be used.
Any connections or junction boxes used should be specifically suited for the application
and installed in accordance with the manufacturers instructions.
Cable Gland Fitting Instructions
The cable gland assembly Fig. 14 (items 1 & 2) provides the necessary protection
against ingress of solid objects and moisture as well as providing cable retention.
Assembly instructions are as follows:-
1) Cable sheath diameter permitted range (6.5 to 9.5 mm).
2) Disassemble cable gland as shown in Fig. 14 and insert cable into position ensuring
‘O’-ring (item1) is placed over cable before the clamping insert (item 2) is tightened.