Stuart Turner TFL Automatic Flow Switch User Manual
Page 17

- 17 -
Cont ...
d) Carefully check pump and pipework for leaks whilst pump running and stationary
before leaving the installation unattended.
For Further Technical Support
Phone the Stuart Turner Pump Assist team on 0844 98 000 97. Our staff are trained to
help and advise you over the phone or arrange for a service engineer to call.
Note: When pumps are installed in another manufacturers original equipment, please
contact the manufacturer for advice.
MAINTENANCE
WARNINGS:
Care should be taken to protect pump from frost and freezing.
Pump Location
If possible site the pump in a location where in the unlikely
event of a liquid leak, any spillage is contained or routed to
avoid electrics or areas sensitive to liquid damage.
1. No routine maintenance is required but provision should be made for easy access to
the pump to allow for repairs due to normal wear and tear.
2. Disconnect electrical supply before working on pump.
3. Turn off liquid supplies to the pump and release pressure by opening outlets before
attempting
maintenance.
4. If the installation is fitted with an inline suction strainer, the strainer must be cleaned
as necessary to ensure the pump has unrestricted flow.
5. After maintenance is completed, refer to commissioning section for instructions on
restarting
pump.
Cleaners, Disinfectants and Descalents
On installations where chemical disinfectants or descalents are periodically
used, the compatibility of the chemical solution regarding the pump must be
considered.
Acid based descalents and aggressive cleaning agents must not come into
contact with the pump. The pump must be removed from the system prior to the
use of these products. The system should be flushed to remove all chemicals
before the pump is reconnected.
If in any doubt as to the suitability of the chemical solutions, please contact our
Pump Assist helpline.
STORAGE
If this product is not installed immediately on receipt, ensure that it is stored in a dry, frost
and vibration free location in its original packaging.