Product description, Motor, Pump – Stuart Turner TFL Automatic Flow Switch User Manual
Page 3

- 3 -
WARNING AGAINST MISUSE
This pump set must not be used for any other application without the
written consent of Stuart Turner Limited and, in particular, must not be
connected directly to the mains water supply or used outside the
conditions specified in the limits of application.
This appliance is not intended for use by persons (including children
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure that they do not play with the
appliance.
PRODUCT DESCRIPTION
Electric motor driven pump complete with automatic control system consisting of flow
switches and electronic controls.
Motor
Induction type, totally enclosed fan ventilated cooling*, class ‘F’ insulation, permanent
capacitor, complying with BS5000 or IEC34-1. All models have integral auto resetting
thermal overload protection.
The standard range of motors are suitable for a supply of 230V, 1 phase, 50Hz.
Optional motors are available on certain models to suit various voltages and frequencies
(see technical specification for details).
*Variations of rating and enclosure details can be found in the technical specification
section.
Pump
All models are close coupled to motor.
RGFL range are of single stage, peripheral design, with vertical suction and discharge
ports.
RGDFL6000 consists of twin pump heads situated at each end of the motor. The pump
design is of the single stage, peripheral design, with vertical suction and discharge ports.
ESFL range are of single stage, end suction, peripheral design.
KFL range are of single stage, end suction, centrifugal design.
LFL range are of four stage, end suction, centrifugal design.
TFL range are of two stage, end suction, centrifugal design.
Standard pump materials of construction of major wetted parts are as follows:-
Model
Body
Impeller
Shaft
Mechanical Seal
RGFL range
Brass
Brass
Stainless Steel
Nitrile/Carbon
Ceramic/Stainless Steel
ESFL range
Brass
Brass
Stainless Steel
Nitrile/Carbon
Ceramic/Stainless Steel
RGDFL6000
Brass
Brass
Stainless Steel
Nitrile/Carbon
Ceramic/Stainless Steel
KFL range
Brass
Acetal
Stainless Steel
Nitrile/Carbon
Ceramic/Stainless Steel
LFL range
Noryl
Stainless Steel
Polycarbonate
Stainless Steel
Nitrile/Carbon
Ceramic/Stainless Steel
TFL range
Noryl
Stainless Steel
Polycarbonate
Stainless Steel
Nitrile/Carbon
Ceramic/Stainless Steel