Cleaners, Disinfectants and Descalents

On installations where chemical disinfectants or descalents are periodically

used, the compatibility of the chemical solution regarding the pump must be
considered.

Acid based descalents and aggressive cleaning agents must not come into

contact with the pump. The pump must be removed from the system prior to the
use of these products. The system should be flushed to remove all chemicals
before the pump is re-connected.

If in any doubt as to the suitability of the chemical solutions refer to Stuart

Turner Ltd.

STORAGE

If this product is not installed immediately on receipt, store in a dry, frost and vibration

free location in its original packaging.

TROUBLE SHOOTING GUIDE

Symptoms

Probable Cause

Recommended Action

Pump will not start.

Electrical supply.

Check power to motor.
Check the circuit breaker is set.
Check the correct fuse is being used.

Internal motor
thermotrip activated.

Wait for thermotrip to cool and auto-reset.
Investigate cause of problem.

Pump runs, but no liquid
is pumped.

Air locked.

Bleed pipework and pump to clear air.

No liquid supply.

Check the supply valves are turned on.
Check outlet not restricted or blocked.

Motor running
backwards.

3 phase only - check motor is rotating in the
correct direction, if not, reverse connections
of any two incoming supply wires.

Connections reversed.

Check liquid connections are on the right way
round.

No flooded suction.

Check the pump has a flooded suction and is
primed.

No footvalves.

If a suction lift exists and pump is not X201
self prime model, fit a Stuart footvalve/strainer
and ensure suction pipework is airtight.