Stuart Turner Kennet 2 User Manual
Page 15

- 15 -
Cont ...
5. Starting
a) Switch on power to the pump which will now be operational.
b) If pump has a three phase supply, confirm the direction of rotation is correct by
stopping and observing over run. The correct direction of rotation is
anti-clockwise when looking directly at the front of the pump casing. To reverse
rotation see wiring diagram section.
c) The pump should now be fully operational.
d) Carefully check pump and pipework for leaks whilst pump running and stationary
before leaving the installation unattended.
For Further Technical Support
Phone the Stuart Turner Pump Assist team on 0844 98 000 97. Our staff are trained to
help and advise you over the phone or arrange for a service engineer to call.
Note: When pumps are installed in another manufacturers original equipment, please
contact the manufacturer for advice.
MAINTENANCE
WARNINGS:
Care should be taken to protect the pump from frost and
freezing.
Pump Location
If possible site the pump in a location where in the unlikely
event of a liquid leak, any spillage is contained or routed to
avoid electrics or areas sensitive to water damage.
1. No routine maintenance is required but provision should be made for easy access to
the pump to allow for repairs due to normal wear and tear.
2. Disconnect electrical supply before working on pump.
3. Turn off liquid supplies to the pump and release pressure by opening outlets before
attempting
maintenance.
4. If the installation is fitted with a footvalve and strainer or inline suction strainer, the
strainer must be cleaned as necessary to ensure the pump has unrestricted flow.
5. After maintenance is completed, refer to commissioning section for instructions on
restarting
pump.
Fig. 19
Priming
Plug
Priming
Plug
Priming
Plug
Kennet
230/1/50
Kennet
400/3/50
Thame
Loddon
X201