beautypg.com

Stuart Turner Pumps - Lifting Station User Manual

Page 9

background image

- 9 -

4 ELECTRICAL

INSTALLATION

4.11

Regulations: The electrical installation must be carried out in

accordance with the current national electrical regulations and installed

by a qualified person.

4.12

Safety: In the interests of electrical safety a 30 mA. residual current

device

(R.C.D. not supplied) should be installed in the supply circuit.

This may be part of a consumer unit or a separate unit.

4.13 Before starting work on the electrical installation ensure the power

supply is isolated.

4.14 This appliance must be earthed.
4.15 The wiring must not be exposed to water.
4.16 The supply cable must be positioned so that it is not stepped on, cut or
damaged.

4.17

Electrical Connection

The unit is provided with a factory fitted supply cord. This must be permanently

connected to the fixed wiring of the mains supply. Means for disconnection must

be incorporated in the fixed wiring in accordance with the wiring rules.

A suitable method of connection would be via a double pole switched, fused

connection unit complying with BS 1363-4, protected with a fuse (see technical

specification).

The connection unit should be mounted in an easily accessible position and

should be labelled if confusion is possible, to allow easy identification of the lifting

station isolating switch.

4.18

Wiring Of Connection Unit

WARNING: This appliance must be earthed.

The wires in the mains lead (supply cord) are coloured in accordance with the

following code:

Green and Yellow: Earth

Blue: Neutral

Brown: Live

As the colours of the wires in the mains lead of this appliance may not correspond

with the coloured markings identifying the terminals in your connection unit

proceed as follows:

The wire which is coloured green and yellow must be connected to the terminal

in the connection unit which is marked with the letter E or by the earth symbol:

or coloured green or green and yellow.

The wire which is coloured blue must be connected to the terminal which is

marked with the letter N or coloured black.

The wire which is coloured brown must be connected to the terminal which is

marked with the letter L or coloured red.